MRIninja Academy
A guided path from MRI physics to running real examinations. The Academy adds order, learning objectives and short checkpoints to pages that already exist in the MRI Library; it does not repeat their content. Experienced users can enter at any level.
Every lesson page has its own study status: To do (the default), In progress, Done or To review. Opening a page from here sets it to In progress; you change it with the menu next to the page. A page added to a lesson later appears as To do with a New tag, and a page revised after you marked it Done is flagged so you can set it to review. Statuses are advice for your own planning and lock nothing.
Spaced review
Questions you miss in a checkpoint come back here after 1, 3, 7 and 14 days, until you answer them correctly at the last step. The queue lives only in this browser (and in your progression code). It is a study aid: nothing is locked.
Your path (optional)
The curriculum is the same for everyone; a path only changes the suggested order and emphasis. Every lesson stays open, switching path never deletes progress, and the choice is stored only in this browser.
Placement test (optional)
Twenty questions spread over levels 1 to 6 suggest where to start and which levels you may skim. It is a rough guide, not an assessment: nothing is locked or skipped automatically, and the result is stored only in this browser.
- Level 0: Orientation
- Level 1: Physics foundations
- Level 2: Image formation and parameters
- Level 3: Sequences
- Level 4: MR safety and patient preparation
- Level 5: Positioning, coils, planning, contrast and gating
- Level 6: Artefacts
- Level 7: Standard protocols by region
- Level 8: Specialist tracks
- Level 9: Capstone: set up the exam
Level 0: Orientation
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
What MRI is, how the scanner is built, and how to use this Academy.
- State what the acronym MRI stands for and what signal an MR image is built from.
- Name the main clinical uses of MRI and examples of examinations performed without contrast media.
- Explain, at an introductory level, why MRI uses no ionising radiation but still has specific hazards.
- Explain why an MR image is a relative, sequence-dependent picture and not a measurement of tissue density.
- Compare MRI with CT at survey level and name the main limits of MRI.
- Name the roles in an MR service: radiologist, technologist, medical physicist and the MR safety roles.
- Name the main applications of MRI beyond the routine hydrogen examination and say, for each, whether the sources describe it as routine, approved for an indication or investigational.
- Name the main hardware blocks of an MRI system and the order of the signal chain.
- Compare superconducting, permanent and resistive magnets and the way each is cooled.
- Explain what shimming is and which shim stages exist.
- Describe the transmit chain and the drive modes of the body coil, and explain why the transmit power is calibrated for each patient.
- Describe how the patient table is docked and removed in an emergency, and state what the evidence says about table speed, bore size and patient symptoms.
- Name the parts of the shielded room and its services, state how RF enclosure attenuation is specified and tested and where the sources disagree, and list the room-side vent, oxygen-monitor, cooling-water and power provisions.
- MRI Scanner Structure and Components — Overview of the Magnet, Gradient System, Radiofrequency System, Table, Shielded Room and Control Electronics
- Superconducting MRI Magnet — Coil Layout, Conductor, Persistent Mode, Cooling Architectures, Quench Engineering and Homogeneity Design
- Permanent, Resistive and Low-Field MRI Magnets — Construction, Open and Dedicated Systems, Comparison with Superconducting Magnets
- MRI Shim System Hardware — Superconducting, Passive and Room-Temperature Shim Stages, Spherical-Harmonic Coils, Dynamic Shimming and Multi-Coil Arrays
- MRI Gradient System Hardware — Coil Geometry and Shielding, Amplifiers, Reported Strength and Slew Rate, Eddy-Current Compensation, Vibration, Cooling and Performance Limits
- MRI RF Transmit System and Body Coil — Transmit Chain, Power Amplifier, Birdcage Body Coil, Quadrature and Two-Channel Drive, Transmit Calibration and Power Monitoring
- MRI Patient Table and Bore — Table Parts and Docking, Table Motion and Field Change, Emergency Removal, Reported Bore Dimensions and Evidence on Bore Size
Every lesson card links to the page that holds the content; the Academy adds order, objectives and a short checkpoint. Checkpoints never block you: you always see "Review lesson" and "Continue anyway". Progress is stored only in this browser. Use "Save or move my progress" at the bottom of the page to get a progression code. For free practice use the Quiz page; for a break, the MRIninja game.
Level 1: Physics foundations
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
The physical principles that every sequence and protocol builds on.
- See how the physics pages are organised and choose a reading order.
- State the Larmor equation and what it relates.
- Explain why a net magnetisation arises from a very small population difference between spin states.
- Describe the effect of a resonant RF pulse on the net magnetisation.
- Define T1, T2 and T2* and how they differ.
- Relate relaxation behaviour to molecular environment.
- Explain the contributions that make up T2*.
- Describe how the flip angle is set and what it changes in the signal.
- Explain the Ernst angle.
- Recognise the main categories of RF pulse design.
- Describe slice selection, frequency encoding and phase encoding.
- Explain what the centre and the periphery of k-space determine in the image.
- Relate the acquisition matrix to k-space sampling.
- Explain why fat and water protons resonate at different frequencies.
- Give the approximate fat–water shift in ppm and the corresponding shift in Hz at a given field strength.
- Identify the consequences for imaging (artefacts and fat suppression).
- Explain the physical basis of flow-related enhancement.
- Describe how motion and diffusion affect the MR signal.
- Define the b-value as a combined diffusion-weighting factor.
- Name the hardware capabilities that modern imaging techniques depend on.
- Explain why shimming is needed for each patient.
- Describe how SNR changes with static field strength and why the gain is not strictly linear.
- Explain the main consequences of higher field for relaxation, SAR and artefacts.
- Contrast SENSE and GRAPPA at a conceptual level.
- Explain why compressed sensing needs incoherent sampling.
- Compare the signal behaviour of stationary tissue and flowing fluid.
Level 2: Image formation and parameters
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
How the acquisition parameters shape contrast, resolution, signal-to-noise ratio and scan time.
- Describe how acquisition parameters trade off against each other.
- State what TR and TE primarily determine in spin-echo and gradient-echo sequences.
- Give typical ranges for common weightings.
- Explain echo spacing in a TSE/FSE train.
- Define the field of view, the acquisition matrix and the slice thickness.
- Explain the difference between the acquisition and the reconstruction matrix.
- Relate these parameters to voxel size and SNR.
- Explain the effect of receiver bandwidth on SNR and chemical shift.
- State the relationship between NEX/NSA and SNR.
- Describe which property of receiver coil arrays parallel imaging exploits.
- Calculate the echo-train duration and the number of echo trains per slice from the turbo factor, echo spacing and number of phase-encoding lines.
- Distinguish phase-direction partial Fourier (fewer lines, SNR cost) from asymmetric echo (shorter minimum TE, no scan-time saving).
- Explain what reference lines and reference scans cost, and how controlled aliasing and the SMS FOV shift change the acquisition.
- Acquisition Bandwidth (Receiver Bandwidth)
- Number of Excitations (NEX) / Number of Signal Averages (NSA)
- Parallel Imaging
- Echo Spacing, Turbo Factor and Echo Trains in Turbo Spin Echo
- Partial Fourier and Asymmetric Echo: Phase, Slice and Readout Direction
- Parallel Acquisition Options: Reference Scans, Simultaneous Multi-Slice and CAIPIRINHA
- Explain what causes fold-over (aliasing) and how phase oversampling prevents it.
- Choose the phase-encoding direction with the artefact in mind.
- Describe how TR, TE, flip angle and presaturation change the signal of flowing fluid.
- Compare 2D multi-slice and 3D acquisition.
- Explain the purpose of the inter-slice gap and what limits the number of slices.
- Describe how multi-slab 3D addresses signal fading with depth.
- Pages G1–G4 and G13 of the geometry series are planned.
Level 3: Sequences
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
The main pulse sequences, how they are built and when each is used.
- Place each sequence in the classification used by the site.
- Recognise why vendor naming differs and how to find the neutral name.
- Define echo train length and effective TE.
- State what the CPMG conditions require of the refocusing pulses.
- Name the main trade-off of increasing the echo train length.
- Explain why a gradient echo needs no 180° refocusing pulse.
- Describe the contrast mechanism of bSSFP and of SWI.
- Explain how the inversion time is chosen to null a tissue.
- Compare STIR and FLAIR and state their typical uses.
- Describe the effect of gadolinium on STIR signal.
- Compare chemical-shift-selective, inversion-based and Dixon approaches.
- Know when each approach fails.
- Describe the principle and typical artefacts of QSM.
- Compare ASL labelling schemes.
- Describe the universal technique for vessel wall imaging.
- Quantitative Susceptibility Mapping (QSM) — Physics, Processing Pipeline, and Brain Clinical Applications
- Arterial Spin Labeling (ASL) — Generic Standard Protocol
- Arterial Spin Labeling — Labeling Scheme Techniques and Parameters
- MRI Vessel Wall Imaging — Universal Technique Master
- MRI Vessel Wall Imaging — Intracranial Arteries (Dedicated Protocol)
- Vascular Lumen, Wall and Perivascular Tissue — MR Anatomy and Signal Semiotics
- Choose between TOF, phase-contrast and non-contrast angiographic techniques.
- Explain flow-related enhancement and how ramped excitation addresses saturation.
- Time-of-Flight MR Angiography (TOF-MRA) — Technique Selection for Intracranial and Cervical Arteries, Reconstruction, Pitfalls and Diagnostic Evidence
- Phase-Contrast MRI — Velocity Encoding in Practice, VENC Selection, Morphological Output (PC-MRA / MRV), Quantitative Output (2D Cine Flow, 4D Flow), Phase Errors and Evidence
- Triggered Non-Contrast-Enhanced MR Angiography — Cardiac-Gated Subtraction, Inflow-Inversion and Quiescent-Interval Techniques (TRANCE, FBI, NATIVE, Inhance Deltaflow, QISS and Equivalents)
- Inflow Inversion-Recovery bSSFP Angiography (b-TFE / B-TRANCE, NATIVE TrueFISP, Inhance Inflow IR, Time-SLIP) — Inversion Geometry, TI, Triggering, Respiratory Strategy, Acceleration and Renal Evidence
- ASL-Based Non-Contrast MR Angiography — Labeling Strategies (PASL, pCASL, Time-Encoded, Superselective), Time-Resolved Readouts, Philips 4D-TRANCE and pCASL-Based 4D-PACK / 4D-S-PACK
- Inflow and Outflow Effects — Quantitative Physics of Flow-Related Enhancement (Progressive Saturation, Critical Velocity) and Time-of-Flight Signal Loss (Washout)
- Ramped (TONE) Excitation in TOF-MRA — Flip-Angle Profile Design, Velocity Dependence, Effect on Stationary Tissue, Field-Strength Limits and Evidence
- Maximum Intensity Projection (MIP) in Angiography — Algorithm, Display Physics, False-Positive and False-Negative Artifacts, Mitigation and Evidence
Level 4: MR safety and patient preparation
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
Zones, hazards, implants, screening and what to do when something goes wrong.
- Name the four MR zones and who may enter each.
- Interpret static-field contour lines and the projectile risk.
- Describe the role of incident learning and governance.
- MRI Safety — Master Page: Hazards, Terminology, Governance, Zones, Operating Modes and Deep-Dive Map
- MR Site Zones and Access Control — Zones I to IV, Categories of Persons, Locks, Signage, Supervision and Emergency Access
- Static Magnetic Field Contours — What Each Field Line Means, the Restrictions Attached to It and How to Read a Field Plot
- Projectile and Torque Hazards in the Static Field — Physics of the Force, Incident Evidence, Objects Involved, Detection Systems and Where the Evidence Stops
- Incident Learning, Governance, Quality and Jurisdictions in MR Safety — What the Surveys Show, What Each Framework Requires of Reporting, Roles and Training, and Where the Documents Differ
- Explain SAR and what increases it.
- Describe the mechanisms of RF burns and how to prevent them.
- State the principles of hearing protection.
- SAR, Bioeffects, and MRI Safety Physics
- Gradient Fields and Peripheral Nerve Stimulation — Thresholds, Operating-Mode Limits, the Cardiac Margin, Sources of Variability and What to Do When a Patient Feels Tingling
- RF Heating and Burns — Mechanisms, Loops and Contact, Conductive Clothing, Tattoos, Positioning and Insulation, and What SAR Does Not Tell
- Acoustic Noise in MRI — Reported Levels, Limits and Hearing Protection, Evidence of Harm, Vulnerable Groups and Noise Reduction
- Explain MR Safe, MR Conditional and MR Unsafe and what a label states.
- Describe the steps before and after scanning a patient with a cardiac device.
- Recognise categories of passive and active implants.
- Implant and Device MR Safety Framework — Test Methods, Label Content and Matching an MR Conditional Label to the Scanner
- Passive Implants and Retained Foreign Bodies in MRI — Aneurysm Clips, Stents, Orthopaedic Hardware, Orbital Metal and Retained Fragments: What the Evidence Shows and Where It Stops
- Cardiac Implantable Electronic Devices in MRI — Hazards, Device Categories, Pathway, Programming, Monitoring and Post-Scan Checks
- Active Implants Other Than Cardiac Devices in MRI — Deep Brain, Spinal Cord, Vagus and Sacral Stimulators, Cochlear and Other Auditory Implants, Drug Infusion Pumps and Glucose Monitors: What the Evidence Shows and Where It Stops
- List the minimum screening questions at scheduling and at the scanner.
- Describe the three physical hazard sources during scanner operation.
- Describe the position on quench and oxygen depletion.
- Describe how claustrophobia and sedation are managed and monitored.
- Cryogens, Quench and Oxygen Depletion in MRI — What Is Measured, What the Guidance States, Where the Vent Path Has Failed, and Where the Evidence Stops
- Claustrophobia, Sedation, Monitoring, MR-Conditional Equipment and Emergencies in the MR Environment — What the Guidance and the Evidence State, and Where They Stop
- Summarise the guidance on pregnant patients and pregnant staff.
- Summarise the consensus positions on gadolinium safety and premedication.
- MRI in Pregnancy and the Pregnant Worker — Fetal Exposure Evidence, Operating Mode and Field Strength, Consent, and Occupational Exposure of Pregnant Staff: Where Guidance Agrees and Differs
- Gadolinium-Based Contrast Agent Safety — NSF, Retention, Hypersensitivity and Premedication, Pregnancy and Lactation, and Where Guidance Differs
Level 5: Positioning, coils, planning, contrast and gating
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
Everything between the patient entering the room and the first sequence.
- Name the anatomical planes and the DICOM patient coordinate directions.
- Interpret patient position codes.
- Describe the landmarking workflow and the coordinate frames involved.
- Recognise the consequences of an offset from the isocentre.
- Distinguish volume and surface coils, and transmit/receive roles.
- Explain array coils and channels.
- Choose a coil for a region.
- Name the parts of the circuit around a receive element (tuning, preamplifier, decoupling, detuning trap, cable trap) and say what each does.
- State what an array adds and does not add compared with a volume coil, and what the comparisons of 8-, 12-, 32- and 96-channel coils show.
- Name the routine and annual checks of coils in the sources, including the weekly element check of a breast coil.
- Patient Planes, Orientation and Positions in MRI — Anatomical Planes, the DICOM Patient Coordinate System, Oblique Prescription and Patient Position Codes
- Laser Positioning, Landmarking, Isocentre and the Scanner Coordinate System in MRI — Table Movement, Offsets, Relation to the Patient Frame and Positioning Quality Control
- Compare macrocyclic and linear agents.
- Explain relaxivity and why agents differ.
- Name non-gadolinium agent classes.
- Describe bolus, test bolus and bolus tracking.
- Explain gating and triggering and when each is used.
Level 6: Artefacts
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
Recognise an artefact, explain its physical origin and choose a remedy.
- Classify artefacts by physical origin.
- Explain truncation (Gibbs) ringing and recognise a zipper artefact.
- Explain the first-kind (misregistration) and second-kind (opposed-phase) chemical shift artefacts.
- Predict the effect of a change in bandwidth or field strength.
- Describe the neutral concepts behind radial and propeller-type motion correction.
Level 7: Standard protocols by region
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
One lesson per master protocol page. Each master holds the standard technique for a region; indication-specific pages are in level 8. Checkpoints for this level are not available yet.
Head
Neck
Spine
Chest
Abdomen
Pelvis
Upper Limb
Lower Limb
Muscle
Whole Body
Level 8: Specialist tracks
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
Optional tracks, each ordered master, technical deep dives, indication pages. A page that is still being written appears as "In preparation".
Cardiac
Neuro and neuro-ophthalmology
Pelvis: rectum and anal canal
Peripheral nerve
Vascular
Level 9: Capstone: set up the exam
Educational material only: not a qualification, no CME/ECM credits. Page links point to https://mri.ninja/.
Case-based exercises where the clinical request is given and you choose preparation, positioning, coil, sequences and contrast. They open when levels 0–7 are mostly live.
Save or move my progress
There are no accounts. Your progress (lesson ids, page statuses, checkpoint scores and dates, no personal data) lives in this browser; clearing site data deletes it. A progression code lets you restore it on another device or keep a copy. Opening the e-mail or WhatsApp link only prepares a message in your own app: MRIninja receives nothing.