MRI Heart for Suspected Myocarditis
MRIninja Knowledge Base | Child Page — Pathology-Specific Protocol
Parent page: Heart master (10101)
Version 1.0 — October 2026
Prerequisite: this page assumes the content of the Heart master (ECG set-up, breath-hold management, view planning, cine, the technique of each module, contrast principles, heart-rate optimisation) and does not repeat it. It documents only what changes when the clinical question is suspected myocarditis (acute or active non-ischaemic myocardial inflammation): which tissue-characterisation modules become mandatory, the updated Lake Louise criteria, timing, slice coverage, thresholds, the differential diagnosis on the images, pericardial involvement, follow-up and the report. Universal safety, device and gadolinium screening are on the general pages and are not repeated.
1. Executive Summary
1.1 Added Value over the Master Protocol
In the master, tissue characterisation is a module that is "mostly optional" for several indications. In suspected myocarditis it becomes the core of the examination: the diagnosis of non-ischaemic myocardial inflammation by cardiovascular magnetic resonance (CMR) rests on the updated Lake Louise criteria of 2018, which require evidence in two categories, one T2-based (myocardial oedema) and one T1-based (injury, extracellular expansion or scar) [1, 2]. A single positive category may support the diagnosis in an appropriate clinical context but with lower specificity [1, 2]. The 2025 European Society of Cardiology (ESC) guideline uses these criteria to classify a CMR study as proving, leaving uncertain or rejecting myocarditis [1].
What changes in practice, relative to the master, is (a) the combination of sequences, which must cover both categories and should include at least one parametric map; (b) the slice coverage and the choice of slice positions for the maps; (c) the timing of the examination relative to symptom onset; (d) the interpretation of the late gadolinium enhancement (LGE) pattern against ischaemic and other non-ischaemic diseases; (e) the assessment of the pericardium; and (f) the structure of the report, which should state which criteria are fulfilled and with which technique [1, 2].
1.2 Limits of the Dedicated Protocol
The technical recommendations are consensus, not trial evidence: the expert recommendations of 2018 state that mapping thresholds are method-specific and should be validated locally [2]. The accuracy data are heterogeneous: the meta-analyses read report significant heterogeneity, use mixed reference standards (clinical criteria or endomyocardial biopsy) and, in the one with the most detail, only 1.5 T data from two vendors [5, 6]. The reference standard itself is imperfect: biopsy is subject to sampling error and to selection bias [2, 8]. The ESC 2025 guideline was read only in part: the recommendation tables are mostly missing from the text read, and classes and levels of evidence quoted here come from a third-party summary (Section 1.3) [1]. No source read specifies how to adapt the protocol to critically ill or unstable patients (to be sourced).
1.3 Evidence Base and Its Reading Level
| Source | Type | Reading level | Used for |
|---|---|---|---|
| ESC Guidelines on myocarditis and pericarditis, 2025 [1] | Guideline (Task Force of the ESC) | Partial: an excerpt of the guideline (most recommendation tables appear only as titles) plus a third-party "comprehensive summary" of unnamed authorship; the bibliographic record was checked in an institutional repository | Role of CMR, categories of CMR result, timing, follow-up, pericardium, role against biopsy |
| Ferreira et al., JACC 2018, updated Lake Louise criteria [2] | Expert panel recommendations (JACC Scientific Expert Panel) | Full text read as rendered by a summarising tool; the text received was truncated (LGE and extracellular-volume acquisition details, field-strength advice and the reference list were not received); several tables were garbled | Criteria, markers, protocol, pitfalls, differential diagnosis, pericardium |
| SCMR standardised protocols 2020 [3] and mapping consensus 2017 [4] | Society consensus | Read for the master (summarising tool); used here only through the master’s statements on myocarditis | Number of breath-holds, slice strategy for focal or acute disease, tissue characterisation in the core protocol |
| Jia et al., 2021 [5] | Systematic review and meta-analysis | Full text read as rendered by a tool | Pooled accuracy of native T1, T2 and ECV |
| Kotanidis et al., 2018 [6] | Systematic review and meta-analysis | Abstract only (repository record) | Areas under the curve of each marker |
| Gaižauskienė et al., 2024 [7] | Systematic review (no pooling) | Abstract only | Per-study accuracy ranges |
| Li et al., 2021 [8] | Single-centre diagnostic study, 3 T, biopsy reference | Full text read as rendered by a tool | Example cut-offs; comparison of the 2009 and 2018 criteria |
| Lurz et al., JACC 2016 (MyoRacer) [9] | Prospective comparison with biopsy | Bibliographic record only; its results are quoted through [2] | Context only |
2. Clinical Context and Decision Making
2.1 What the Examination Is Asked to Do
For suspected myocarditis, the ESC 2025 guideline places CMR as a non-invasive tool that characterises oedema, ischaemia and necrosis or fibrosis, and states that it parallels, rather than replaces, endomyocardial biopsy: CMR does not identify the histological type (viral, immune-mediated or other), and biopsy remains needed in selected cases [1]. Coronary disease is addressed by invasive angiography or computed tomography angiography depending on clinical probability [1]. The third-party summary of the guideline assigns CMR for suspected myocarditis Class I, Level B, and echocardiography Class I as first-line; FDG-PET/CT is listed as Class IIa when echocardiography and CMR are inconclusive, in particular for sarcoidosis [1]. These classes and levels were not verified in the guideline text itself.
2.2 Categories Used by the Guideline
| Element | Definition as read | Source |
|---|---|---|
| Definite myocarditis | Compatible clinical presentation with CMR- or biopsy-proven findings | [1] |
| Possible myocarditis | Clinical presentation with at least one additional criterion | [1] |
| Unlikely / rejected | Clinical presentation without additional criteria | [1] |
| CMR-proven | Both updated Lake Louise categories fulfilled | [1] |
| CMR-uncertain | One category fulfilled | [1] |
| CMR-rejected | Negative CMR | [1] |
| Complicated acute myocarditis | Acute myocarditis plus at least one of: left-ventricular ejection fraction below 50%, sustained ventricular arrhythmia, advanced heart block, heart failure, cardiogenic shock | [1] |
| Fulminant | Acute onset with haemodynamic instability requiring inotropes or mechanical circulatory support | [1] |
(Reasoning) The report categories of Section 6 are written to map onto the three CMR categories of the guideline, so that the clinician can use the result directly. Whether a given patient is stable enough for a 40-minute examination is a clinical decision that no source read addresses.
2.3 Timing
The expert recommendations state that the sensitivity of the oedema-based and injury-based markers is limited to "a few weeks" after presentation, and that follow-up imaging is recommended to confirm or exclude persisting active inflammation [2]. The third-party summary of the ESC guideline states that diagnostic accuracy is highest within the first two weeks from symptom onset and recommends a follow-up CMR within six months (Class I, Level B in that summary), to separate healing from ongoing disease and to inform risk stratification and the return to exercise [1]. The panel text also reports that acute inflammation was typically studied within 14 days in the cited data (a MyoRacer threshold) [2]. The two-week figure comes from a secondary source and from a study that is itself quoted indirectly.
(Reasoning) Because the markers fade, the date of symptom onset and the date of the examination are essential data for the radiologist and should be recorded on the request and in the report (Section 6).
3. Dedicated Protocol Design: What Changes from the Master
3.1 Differences from the Master Protocol
| Element | Master (10101) | Change for suspected myocarditis | Source |
|---|---|---|---|
| Tissue characterisation | Optional for several indications; early gadolinium enhancement "may be added" in myocarditis | Core of the examination: at least one T2-based and one T1-based marker, to satisfy both categories | [2, 3] |
| T2-based marker | T2-weighted imaging or T2 mapping | T2 mapping is described as a reliable marker of oedema and an alternative to T2-weighted imaging; regional or global high T2 signal, or a regional or global increase in T2 relaxation time, counts as positive | [2] |
| T1-based marker | Native T1 mapping, ECV, LGE listed as modules | Increased native T1, increased ECV, or LGE with a non-ischaemic distribution; T1 mapping is an alternative to early gadolinium enhancement | [2] |
| Coverage | Slice position of maps depends on whether disease is diffuse, patchy or focal | Full left-ventricular coverage is recommended for tissue characterisation; for mapping, at least three short-axis slices at base, mid-ventricle and apex of the central third; for focal or acute disease, maps covering the most abnormal area and an area of apparent minimal abnormality | [2, 4] |
| Slice position of T1 and T2 maps | Same slices before and after contrast (for ECV) | T1 and T2 maps at the same slice positions as each other | [2] |
| Breath-holds | About 16–25 for myocarditis, acute infarction or regional disease (T1 mapping) | Unchanged; this is the stated figure for myocarditis | [4] |
| Cine | Short-axis stack and long axes | Cine also supplies the supportive criteria: systolic wall-motion abnormality, left-ventricular dysfunction and pericardial effusion | [2] |
| Rhythm | Diastolic readout when regular | For fast or irregular rhythm, late- or end-systolic acquisition is recommended for the mapping | [2] |
| LGE | 2D inversion-recovery or PSIR, confirm in an orthogonal plane | Acquired about 10 minutes after contrast; LGE must not be used in isolation; it cannot reliably separate recent from remote myocarditis | [2] |
| Early gadolinium enhancement (EGE) | Mentioned as an addition in myocarditis | An alternative T1-based marker; the cut-off quoted is a relative signal increase of 45% of myocardium versus skeletal muscle, with the caveat that values vary by system; removing EGE did not significantly reduce accuracy in a study cited by the panel | [2] |
| Field strength | 1.5 T / 3 T considerations | At 3 T, volume-selective B0 shimming focused on the heart is essential | [2] |
| Pericardium | Not specific | Review the pericardium on cine, LGE and maps (Section 5.3) | [1, 2] |
| Perfusion / stress | Module of ischaemia protocols | Not part of the protocol for suspected myocarditis in the sources read; whether first-pass perfusion adds information is not addressed (to be sourced) | — |
3.2 Suggested Order of Modules
The master gives the general order (localisers and view planning, cine, tissue characterisation before contrast, perfusion, contrast, LGE, post-contrast T1 for ECV). For suspected myocarditis the order of the master is kept and the tissue characterisation modules are expanded: cine with long axes; T2 mapping and/or T2-weighted imaging; native T1 mapping at matched slice positions; contrast; optional EGE; LGE in short-axis and long-axis planes about 10 minutes after contrast with orthogonal confirmation; post-contrast T1 mapping for ECV when planned, 10 to 30 minutes after the bolus [2, 3, 4]. (Reasoning) Acquiring all pre-contrast maps before gadolinium avoids any interaction between contrast and native values, and the matched slice positions allow a voxel-wise comparison of oedema and T1 findings and of ECV.
3.3 Reference Ranges and Thresholds
The expert panel states that native T1 thresholds are method-specific and should be benchmarked against published norms and validated locally, and that published or local normal values, left-ventricular coverage and proper analysis tools "must be acknowledged" [2]. The mapping consensus gives the same rule: if no local range exists for native T1 or T2, quantitative results should not be reported clinically [4]. The table below lists the example values read, as examples of magnitude, not as recommended cut-offs.
| Marker | Value | Context | Source |
|---|---|---|---|
| Native T1 | 1,228 ms (sensitivity 86.0%, specificity 93.3%, AUC 0.90) | Single centre, 3 T, 73 patients (43 biopsy-positive), biopsy reference; the authors state that mapping values depend on field strength and technique | [8] |
| T2 mapping | 58.5 ms (sensitivity 83.7%, specificity 93.3%, AUC 0.90) | Same study | [8] |
| ECV | 31.0% (sensitivity 65.1%, specificity 83.3%, AUC 0.78) | Same study | [8] |
| Weighted mean difference myocarditis versus controls | Native T1 69.15 ms (I² 90%); T2 5.42 ms (I² 18%); ECV 4.32% (I² 10%) | Meta-analysis, 1.5 T only, two vendors | [5] |
| T2-weighted signal ratio | A ratio of 2.0 is cited as abnormal (passage fragmented in the text read) | Black-blood STIR; limited by low signal-to-noise ratio, motion and arrhythmia; possible false negatives when skeletal muscle is also inflamed | [2] |
| Early gadolinium enhancement | 45% relative signal increase | Values vary by system | [2] |
Because the mean difference of native T1 shows major between-study heterogeneity (I² 90%), and the cut-offs in [8] come from one 3 T system, the values above must not be adopted without a local reference range acquired with the same sequence, field strength and analysis method [2, 4, 5, 8].
3.4 Contrast
Contrast principles are in the master and do not change. The expert panel’s EGE protocol uses a standard dose of 0.1 mmol/kg followed by a 25 mL saline flush at 1.5–2 mL/s, with a repeat of the baseline scan and an optional second 0.1 mmol/kg dose after the post-contrast series (total 0.2 mmol/kg if renal function permits) [2]; this text was received as rendered by a tool and is partly garbled, so the doses must be checked against the original (Section 10). The imaging agent, the dose and the renal safety are governed by Gadolinium Contrast Agent Safety.
4. Diagnostic Criteria and Performance
4.1 The Updated Lake Louise Criteria (2018)
| Category | Criterion | Notes |
|---|---|---|
| Main criterion 1: T2-based (oedema) | Regional high T2 signal, or global T2 signal ratio, on T2-weighted images | Black-blood STIR typical; T2 signal ratio limited by signal-to-noise ratio, motion and arrhythmia [2] |
| Regional or global increase in T2 relaxation time (T2 mapping) | Reliable marker of oedema; alternative to T2-weighted imaging [2] | |
| Main criterion 2: T1-based (injury) | Increased native T1 | Sensitive but not specific; also raised by fibrosis, infiltration and other chronic changes [2] |
| Increased ECV | Needs haematocrit; incremental value beyond LGE needs more evidence [2] | |
| Early gadolinium enhancement ratio, or LGE with non-ischaemic distribution | EGE is an alternative to T1 mapping; if T1 mapping is paired with LGE, the T1 abnormality should lie beyond the LGE-detected areas [2] | |
| Supportive criteria | Pericardial effusion on cine; high pericardial signal on LGE; abnormal pericardial T1 or T2 mapping; systolic wall-motion abnormality; left-ventricular dysfunction | Listed by the panel as supportive; the text read does not state a rule for using them without a main criterion [2] |
4.2 How the Criteria Are Applied
In a patient with a significant pre-test probability, CMR gives strong evidence of acute inflammation if at least one criterion is positive in each of the two main categories [2]. The abstract of the panel states that a single positive marker may still support the diagnosis in an appropriate clinical context, with lower specificity [2]. The ESC guideline excerpt reads "at least one T2-based criterion plus ideally one T1-based criterion", and states that having both categories increases specificity; its categories (CMR-proven, uncertain, rejected) correspond to two, one or no category fulfilled [1]. The third-party summary phrases the same rule as at least one of each category [1]. The wording therefore differs slightly between sources (a point to state in the report; Section 11).
4.3 Diagnostic Performance
| Source | Design | Marker | Result |
|---|---|---|---|
| Jia 2021 [5] | 10 studies (2014–2019), 400 patients, 266 controls; 7 studies with clinical criteria and 3 with biopsy as reference; 1.5 T, two vendors | Native T1 | Sensitivity 0.84 (0.78–0.88), specificity 0.86 (0.69–0.95), AUC 0.87 (0.84–0.90) |
| T2 | Sensitivity 0.77 (0.69–0.83), specificity 0.83 (0.73–0.89), AUC 0.86 (0.82–0.89) | ||
| ECV | Sensitivity 0.69 (0.50–0.83), specificity 0.77 (0.63–0.87), AUC 0.80 (0.76–0.83) | ||
| Kotanidis 2018 [6] | 22 studies of adults with suspected acute myocarditis, searched to April 2017, QUADAS-2; heterogeneity too large for pooled sensitivity or specificity (hierarchical ROC only); original 2009 criteria | Native T1 mapping | AUC 0.95 (0.93–0.97) |
| T2 mapping | AUC 0.88 (0.85–0.91) | ||
| LGE | AUC 0.87 (0.84–0.90) | ||
| ECV | AUC 0.81 (0.78–0.85) | ||
| Lake Louise criteria (2009) | AUC 0.81 (0.77–0.84) | ||
| T2 ratio / signal | AUC 0.80 (0.76–0.83) | ||
| EGE | AUC 0.78 (0.74–0.81) | ||
| Gaižauskienė 2024 [7] | 13 studies, 686 patients with suspected myocarditis and 372 controls; no pooled estimates in the abstract | Native T1 | Accuracy 69–99%; sensitivity 64–98%; specificity 87–100% |
| T2 | Accuracy 47–87%; sensitivity 48–94%; specificity 60–92% | ||
| ECV alone | Accuracy 62–76%; sensitivity 47–73%; specificity 76–90%; combined T1/T2/ECV with LGE up to 96% accuracy | ||
| Li 2021 [8] | Single centre, 3 T, 73 patients, biopsy reference | 2009 criteria | Sensitivity 79.1%, specificity 73.3%, AUC 0.76 |
| 2018 criteria | Sensitivity 95.3%, specificity 86.7%, AUC 0.91 | ||
| LGE alone | Sensitivity 76.7%, specificity 70.0%, AUC 0.73 |
Appraisal. Native T1 mapping consistently has the highest point estimates, with T2 mapping next, and ECV and the classical markers lower [5, 6]. The quality of this evidence is limited by: heterogeneity (significant in [6]; I² of 82% for native T1 specificity and 78% for ECV sensitivity in [5]); mixed reference standards, with specificity lower in biopsy-referenced studies than in those using clinical criteria (native T1 0.63 versus 0.92, T2 0.68 versus 0.89 in [5]); unclear blinding of the index test in 8 of 10 studies in [5]; 1.5 T data from two vendors only in [5]; a single-centre sample of 73 with 28.8% of patients biopsied before CMR in [8]; and biopsy false negatives from sampling error [8]. (Reasoning) The areas under the curve of [6] come from different subsets of studies and should not be treated as a head-to-head ranking. Studies that tested the 2018 criteria directly are few in the sources read; the only one read in detail is the single-centre study [8].
5. Interpretation Specific to Myocarditis
5.1 LGE Distribution and Pattern
Myocarditis lesions are typically subepicardial or mid-wall, whereas ischaemic injury is subendocardial [2]. LGE used alone is not recommended for the diagnosis, and LGE cannot reliably distinguish recent from remote myocarditis [2]. Eosinophilic myocarditis is described with circumferential subendocardial LGE, and giant-cell myocarditis with large subendocardial areas, so that a subendocardial pattern does not by itself prove an ischaemic cause [2]. The relation between the segmental location of the lesion and the aetiology is not stated in the text read (to be sourced).
5.2 Differential Diagnosis on the Images
| Entity | Feature that matters on CMR, as stated | Source |
|---|---|---|
| Ischaemic injury | Must be excluded; subendocardial rather than subepicardial or mid-wall lesions | [2] |
| Cardiac sarcoidosis | LGE present in 19–26% in the studies cited; T2 values were paradoxically lower in LGE regions in one cited study | [2] |
| Takotsubo syndrome | Oedema-type inflammatory features but typically no LGE | [2] |
| Infiltrative disease (for example amyloidosis) and diffuse fibrosis | Can raise native T1 and ECV, so a T1 abnormality alone is not specific for inflammation | [2] |
| Venous congestion in acute decompensated heart failure | Can cause myocardial oedema | [2] |
| Eosinophilic and giant-cell myocarditis | Subendocardial LGE patterns as above | [2] |
| Systemic and other causes | Listed in the panel: pheochromocytoma, systemic lupus erythematosus, rheumatoid arthritis, systemic sclerosis, Chagas disease, HIV infection, hyperthyroidism and checkpoint-inhibitor myocarditis; imaging features are not detailed in the text read (to be sourced) | [2] |
5.3 Pericardial Involvement
A pericardial effusion alone does not prove pericarditis, since it may reflect heart failure [2]. Pericardial inflammation is suggested by thickening, high T2 or T1-mapping signal, or abnormal LGE; a thickness above 3 mm is listed in the panel’s table, a value to be checked against the original because that table was garbled in the text received [2]. The ESC guideline states that CMR provides non-invasive confirmation of pericarditis beyond clinical criteria and is superior for tissue characterisation, showing pericardial oedema and pericardial LGE, and links extensive pericardial LGE to higher risk and absence of pericardial LGE to lower risk [1]. In the summary, CMR for pericarditis is Class I, Level B when clinical criteria do not allow the diagnosis, and computed tomography is recommended for pericardial assessment [1]. Detailed pericardial technique (for example the sequence for pericardial thickness) is not documented in the sources read (to be sourced).
5.4 Follow-up Examination
The ESC summary recommends follow-up CMR within six months. Persistent oedema suggests ongoing inflammation, new or increasing LGE suggests progression, and resolved oedema with stable or decreasing LGE suggests healing; the summary also quotes prognostic data on persistent LGE with oedema whose original study was not identified in the text read (to be sourced) [1]. The expert panel recommends follow-up imaging to confirm or exclude active inflammation [2]. (Reasoning) For follow-up to be interpretable, the protocol, the slice positions, the sequences and the reference ranges should match those of the baseline study, as in any quantitative serial comparison.
6. Reporting Framework
The master lists the generic reporting items. For suspected myocarditis the report should add the following, written so that the final statement maps onto the guideline categories of Section 2.2 (Reasoning).
| Item | Content | Basis |
|---|---|---|
| Timing | Date of symptom onset (or presentation), date of the examination, and the interval between them | Timing sensitivity [1, 2]; Reasoning |
| Technique | Field strength; which T2-based and T1-based markers were acquired; mapping scheme; contrast and timing of LGE | [2, 4] |
| T2-based criterion | Present or absent; technique; regional or global; values with the local reference range and Z-score if available | [2, 4] |
| T1-based criterion | Present or absent; which marker (native T1, ECV, EGE or LGE); regional or global; values with local reference range; haematocrit used for ECV | [2, 4] |
| LGE | Presence; distribution (subepicardial, mid-wall, subendocardial, transmural); segments; whether confirmed in a second plane | [2, 3] |
| Function | Left-ventricular ejection fraction; regional wall motion; right ventricle where relevant | Supportive criteria [2] |
| Pericardium | Effusion; thickening; pericardial signal on T2, mapping or LGE | [1, 2] |
| Alternative diagnosis | Whether features favour ischaemic, sarcoid, takotsubo, infiltrative or other cause | [2] |
| Conclusion | Both categories fulfilled / one category fulfilled / no category fulfilled; the report does not infer the aetiology | [1, 2] |
7. Technical Pitfalls
Late examination: the markers lose sensitivity after a few weeks, so a negative study late after onset does not exclude earlier inflammation [2]. LGE as the only marker: not recommended in isolation [2]. Thresholds borrowed from another system: cut-offs are method-specific; a value from a different sequence, field strength or vendor is not valid [2, 4]. T1 abnormality overlapping LGE: when T1 mapping is paired with LGE as the T1-based criterion, the T1 abnormality should lie beyond the LGE-detected areas [2]. Skeletal muscle reference: for the signal-ratio methods the muscle region must avoid the left upper arm, where edge effects near the bore periphery may corrupt values, and should be taken in the serratus anterior or latissimus dorsi [2]. Arrhythmia and tachycardia: late- or end-systolic acquisition is recommended for the mapping [2]. Breathing: deep irregular breathing, snoring or sleep-related breathing severely degrades image quality; motion correction corrects only in-plane motion; slices near the diaphragm or apex are more oblique and suffer greater volume averaging [2]. 3 T: volume-selective B0 shimming focused on the heart is essential [2]. Devices: parametric mapping is unreliable with a pacemaker or defibrillator unless special shimming or sequences are used [4]; see Cardiac Implantable Devices in MRI.
8. MRI Technologist Pearls
8.1 Before the Examination
Record the date of onset of symptoms and any recent treatment on the request, since the interval to the examination affects the interpretation [2] (Reasoning for the practical point). Obtain the haematocrit on the day if ECV is planned [4]. Check the ECG signal before moving the patient into the bore (master); patients presenting with possible myocarditis may have arrhythmia, so the trigger indicator must be checked on the trace (Reasoning).
8.2 During the Examination
Plan the T2 and T1 maps at the same slice positions: base, mid and apex of the central third, and add a map through the most abnormal region on the T2-weighted or cine images when a focal abnormality is apparent [2, 4]. Choose a late- or end-systolic readout when the rhythm is fast or irregular [2]. Acquire the LGE about 10 minutes after contrast and confirm any enhancement in a second plane (master and [2]). Keep the pre-contrast maps ahead of the contrast injection (Reasoning).
8.3 Common Errors (Reasoning)
(1) Acquiring LGE only, because it is the familiar module; (2) shifting the slice positions between T2 and T1 maps, which prevents a regional comparison; (3) using the maps without the local reference range; (4) forgetting the pericardium and the cine for effusion and wall motion; (5) not recording the interval from symptom onset; (6) leaving the 3 T cardiac shim unchecked. None is documented as an error rate in a source read.
9. Quality Control Checklist
| Check | Basis |
|---|---|
| Interval between onset and examination recorded | [1, 2]; Reasoning |
| At least one T2-based and one T1-based marker acquired | [2] |
| Full LV coverage or at least three matched short-axis slices (base, mid, apex) for maps | [2] |
| T1 and T2 maps at identical slice positions | [2] |
| Late- or end-systolic readout chosen when rhythm fast or irregular | [2] |
| LGE about 10 minutes after contrast; confirmed in a second plane | [2]; master |
| Local reference range available for each mapping value reported | [2, 4] |
| Haematocrit available if ECV reported | [4] |
| 3 T: cardiac B0 shim verified | [2] |
| Cine reviewed for effusion, wall-motion abnormality and ejection fraction | [2] |
| Report states which categories are fulfilled | [1, 2] |
10. Advanced Technical Parameters
The values below are those received from the expert panel text [2] (rendered by a tool, partly garbled; check against the original) and from the master’s sources [3, 4]. Parameters not given in the sources are not invented.
| Parameter | Value stated | Source |
|---|---|---|
| T2-weighted imaging | Fast spin echo, short-axis, with fat suppression; dual-echo option with TE1 about 65 ms and TE2 120–130 ms; TE 65 ms for the body-coil T2 ratio | [2] |
| T2 mapping and T1 mapping | Same slice positions; vendor sequences; slice thickness 6–8 mm, in-plane about 1.6–2.0 mm (master); at least three source images for T2 mapping, example TE 0, 25, 50 ms (master) | [2, 3, 4] |
| Minimum coverage for maps | At least three short-axis slices near base, mid and apex of the central third; full LV for tissue characterisation | [2] |
| Rhythm | Late- or end-systolic acquisition for fast arrhythmic or high-rate cases | [2] |
| EGE acquisition | Pre- and post-contrast T1 spin-echo stacks, axial (short-axis sometimes used), quiet respiration, inferior to superior so that the superior LV border is reached at end-systole; 7.0 mm slices, 1.5 mm gap, Y-resolution 128, 4 averages, fast spin echo turbo factor 2, body coil, about 4 minutes; saturation band over the atria | [2] |
| EGE contrast | 0.1 mmol/kg followed by 25 mL saline at 1.5–2 mL/s; post-contrast scan started once the bolus is delivered and finished within 4 minutes; baseline repeated with identical parameters; second 0.1 mmol/kg after the post-contrast series (total 0.2 mmol/kg) if renal function permits | [2] |
| EGE analysis | Myocardial regions in at least three central slices excluding bright endocardial blood and epicardial fat; skeletal-muscle reference region in the serratus anterior or latissimus dorsi, avoiding the left upper arm | [2] |
| LGE | Inversion-recovery gradient echo about 10 minutes after contrast; not used in isolation; acquisition details of the panel were not received | [2] |
| ECV | Formula, contrast and timing as in the master (post-contrast T1 10–30 minutes after administration; haematocrit) | [4] |
| 3 T | Volume-selective B0 shimming focused on the heart | [2] |
11. Evidence Gaps and Ongoing Debate
Single threshold: no universal cut-off exists for native T1, T2 or ECV; thresholds are method-specific and local ranges are required [2, 4]. The cut-offs of [8] come from one 3 T centre.
Wording of the diagnostic rule: the guideline excerpt speaks of one T2-based criterion "plus ideally" one T1-based criterion; the panel and the summary require one criterion in each category; the panel also accepts a single marker in the right context with lower specificity [1, 2]. The practical consequence for the "CMR-uncertain" category is not detailed in the text read (to be sourced).
Added value of ECV and EGE: the incremental value of ECV beyond LGE needs more evidence, and removing EGE did not significantly reduce accuracy in a study cited by the panel [2]; ECV has the lowest sensitivity in the meta-analyses [5, 6].
Chronic or late myocarditis: the panel reports that, in the MyoRacer study, native T1 reached 81% accuracy in the acute group and 45% in the chronic group, and T2 mapping was the only parameter with acceptable accuracy (73%) in chronic myocarditis; these are second-hand figures from the text received and the primary paper [9] was not read [2].
Reference standard: biopsy is subject to sampling error and selection bias, and whole-heart histology is not practical [2, 8]; specificity estimates depend on the reference standard [5].
Quality of the underlying meta-analyses: the original 2009 criteria are the subject of [6]; the 2018 criteria are tested in [8] (single centre). The Kotanidis figures quoted by the panel as rendered (sensitivity 78%, specificity 88%, AUC 83) cannot be reconciled with the abstract read here (Lake Louise AUC 0.81) (to be sourced); the abstract was used.
Class and level of recommendation: taken from a third-party summary of the ESC guideline and not verified against the guideline tables [1].
Sources not read: the full ESC 2025 guideline text (recommendation tables, CMR chapter); the full text of Kotanidis [6] and of MyoRacer [9]; the original Lake Louise criteria of 2009; an updated meta-analysis of parametric mapping under the modified criteria, identified by search and not read; the reference list of the expert panel text (to be sourced).
Not covered by any source read: myocarditis after vaccination or in athletes, return-to-sport decisions, immune-checkpoint-inhibitor myocarditis in detail, paediatric protocols, imaging in unstable or ventilated patients, the role of first-pass perfusion, stress CMR, and artificial intelligence (to be sourced).
12. Evidence-Based References
References are ordered by level of evidence and then by recency. The reading level of each source is stated in its line; a source read only at abstract level supports only what its abstract states.
A. Guidelines / Consensus / Society Recommendations
B. Systematic Reviews / Meta-analyses
C. Important Prospective / Original Studies
D. Technical MRI Papers
No dedicated technical sequence paper on myocarditis imaging was read for this page (to be sourced).
E. Landmark Historical References
The original Lake Louise consensus criteria (Friedrich et al., J Am Coll Cardiol 2009) were not read; they are known only through [2] (to be sourced).
Related Protocols
Recent PubMed search for this protocol