Prerequisite: this page assumes the Heart master, in particular Section 4.6 (LGE technique: sequence types, TI set to null normal myocardium, TI scout, PSIR, "etched" appearance, readout every heartbeat or every second or third heartbeat) and Section 10.2 (LGE parameter table), and does not repeat them. It documents what the master does not: the signal behaviour behind the TI choice and what PSIR changes, the dark-blood LGE techniques and their limits, the pattern-based reading of LGE, the quantification methods and how much they disagree, reporting items specific to LGE, and the pitfalls. Disease-specific use of LGE is in the child pages (myocarditis: 10102).

1. Executive Summary

1.1 Added Value over the Master Protocol

The master gives the LGE recipe. This page explains why the recipe is built that way and where it fails. Three points matter most in practice. First, magnitude inversion-recovery images depend strongly on the inversion time: in the original phase-sensitive inversion recovery (PSIR) study, the infarct area measured with a TI 75 ms too early was roughly half of the area measured at the null point on magnitude images, whereas on phase-sensitive images it was unchanged [7]. Second, conventional bright-blood LGE can hide subendocardial scar because blood and scar may be equally bright, which is the reason for the dark-blood family of techniques, whose superiority for subendocardial ischaemic scar the reviewers of the field call proven, while their value for non-ischaemic scar is largely unknown [4]. Third, LGE volume depends on the quantification method: in one reproducibility study, a 2-SD threshold gave volumes up to twice those of other methods, and full width at half maximum (FWHM) was the most reproducible [6]; the SCMR post-processing document declines to name an optimal method [2].

1.2 Limits of the Page

Several sources were read only partly. Two original studies were read at abstract or record level (Flett 2011, Kim 2000) and support only what their abstracts state [6, 8]. Technical numbers are old and platform-specific: the PSIR timing and signal figures come from a 1.5 T study of 2002 on one vendor platform [7]. The consensus documents give no numerical nulling TI and no 3D-specific values [1]. The dark-blood literature is mostly single-centre and uses mixed reference standards; only two of the methods reviewed were validated against histology [4]. Pattern-to-disease associations come from a narrative review of 2014 [5]. Points that are not in any source read are marked (Reasoning) or (to be sourced).

1.3 Evidence Base and Its Reading Level

SourceTypeReading levelUsed for
Kramer et al., SCMR protocols 2020 [1]Society consensus documentLGE sections read as rendered by a summarising tool (two readings)Timing, TI, long-TI and short-TI variants, dark-blood statement
Schulz-Menger et al., SCMR post-processing 2020 [2]Society consensus documentLGE section read as rendered by a summarising toolVisual assessment, pattern, transmurality bins, quantification statements, artefacts
Ferreira et al., JACC 2018 [3]Expert panel recommendationsPartial (read for page 10102; text truncated)Only the statement that LGE alone is not recommended for myocarditis
Holtackers et al., JCMR 2021 [4]Narrative reviewFull text as rendered by a summarising toolDark-blood techniques, validation figures, limitations, authors' conclusions
Satoh et al., World J Cardiol 2014 [5]Narrative reviewFull text as rendered by a summarising toolLGE distribution by disease
Flett et al., JACC Imaging 2011 [6]Original study (60 patients)Abstract/record level onlyComparison of quantification methods
Kellman et al., Magn Reson Med 2002 [7]Technical original studyFull text as rendered by a summarising toolPSIR principle, TI sensitivity
Kim et al., N Engl J Med 2000 [8]Landmark original studyAbstract onlyQualitative link between transmural extent and functional recovery

2. Signal Behaviour and TI Strategy

2.1 Magnitude Versus Phase-Sensitive Images

An inversion-recovery image acquires a longitudinal magnetisation that starts negative and recovers through zero. A magnitude image displays the absolute value, so tissue with a long T1 that is still below the zero crossing can appear bright and be mistaken for enhancement [2]. A phase-sensitive reconstruction removes the background phase and keeps the sign of the magnetisation, so the sign (polarity) is preserved [7]. In the original implementation a low-flip-angle reference image acquired in alternate heartbeats within the same breath-hold supplied the background phase and the coil sensitivity, and the phase-sensitive image was normalised by it [7].

2.2 What the Original PSIR Study Measured

Measurement (1.5 T, one vendor, 2002)ResultSource
Infarct area, TI 75 ms early, magnitude: ratio to the area at the null TI (N = 9)0.54 ± 0.17 (area 224 ± 143 vs 387 ± 181 mm²)[7]
Same comparison, phase-sensitive images1.00 ± 0.10 (area 433 ± 239 vs 421 ± 212 mm²)[7]
Magnitude contrast-to-noise ratio when TI is set 15 ms too earlyFalls by about 25%[7]
Drift of the optimal null during a 5–7 min stack of slicesAbout 15–25 ms[7]
Infarct size, phase-sensitive over magnitude, both at the null TI (N = 9)1.07 ± 0.09 (P = 0.05)[7]
Blood-to-normal-myocardium CNR (N = 20)7.8 ± 2.7 magnitude; 8.7 ± 2.2 phase-sensitive[7]
Failure mode reportedSevere microvascular obstruction caused a sign error in 1 of 25 cases[7]

The study defined no numerical TI window and had no histological or outcome reference and no sensitivity or specificity data; the authors asked for evaluation in a larger population [7]. The practical reading is that TI drift across a stack of slices is a measurable source of error on magnitude images and a minor one on phase-sensitive images, which is the reason PSIR is preferred when available (Reasoning, based on [7] and on the master).

2.3 Choosing the TI Strategy

SituationApproachBasis
PSIR availableUse it as the default LGE sequence; a nominal TI can replace a patient-specific null, but the master's rule (set a TI that nulls normal myocardium) remains the starting point[1, 7]
Magnitude only, long stack of slicesRe-check the null during the stack, since the optimum drifts; when in doubt, prefer a TI slightly too long over one too short[2, 7]
Suspected no-reflow or mural thrombusAdd a long-TI image (about 550 ms at 1.5 T and 850 ms at 3 T in the LGE section; the cardiac-masses section of the same document gives 500–550 ms and 850–900 ms for thrombus nulling)[1]
Subendocardial scar suspectedShort-TI PSIR (about 200 ms) or dark-blood LGE (Section 4)[1, 4]
Dark-blood LGETI depends on the specific sequence; the consensus document gives no numerical value[1]

The numerical nulling TI for normal myocardium is not given in the LGE section of the consensus document; the long-TI and short-TI values above are the only TI numbers it states there [1]. This closes the apparent discrepancy noted on the master: the figures quoted in the master (10.2) are those of the document, and the document gives no numerical nulling TI (Section 11).

3. Acquisition Choices Beyond the Master

3.1 Confirming That an Enhancement Is Real

Bright ghosting artefacts arise from poor ECG gating, poor breath-holding and from long-T1 fluid such as cerebrospinal fluid or pleural effusion [2]. The post-processing document asks that an area of enhancement be seen as higher signal than the nulled myocardium and be verified in at least one orthogonal plane, or on a second image acquired after changing the readout (phase-encoding) direction [2]. Changing the direction moves ghosting and truncation artefacts but not true tissue signal (Reasoning).

3.2 Single-Shot and 3D Acquisitions

A single-shot bSSFP readout is described as an optional second set or as a back-up for irregular rhythm or poor breath-holding [1]. The same document states no 3D-specific resolution, slice or timing value [1]. Where the cost of single-shot acquisition (lower resolution and signal-to-noise ratio) is accepted, it should be stated in the report (Reasoning).

3.3 Timing After Contrast

The master already states at least 10 min after injection. Two additions from the dark-blood review: bright-blood LGE acquired at about 20 instead of 10 min gives a higher scar-to-blood contrast through blood-pool washout, but the authors call this inefficient and often unsuitable for daily practice [4]; and some dark-blood preparations may not work well soon after the injection [4].

4. Dark-Blood LGE

4.1 Why It Exists

With standard inversion recovery, the TI nulls myocardium, not blood. Blood may therefore appear as bright as adjacent subendocardial scar, which can make scar look like blood pool (smaller apparent scar) or blood look like scar (false positive) [4]. Dark-blood techniques suppress the blood signal so that the endocardial border remains visible.

4.2 Techniques, Validation Figures and Limits

Technique (first author, year)PrincipleReported evidenceStated limits
T2 preparation then IR (Liu 2008)T2 preparation before inversionScar-to-blood CNR +32% (5 healthy, 9 patients)Per-patient optimisation of effective TE and TI
IR then T2 preparation (Kellman 2016; Francis 2017; Basha 2018; Fahmy 2018)T2 preparation after inversion; black-blood or gray-blood variantsFrancis: 172 patients, more segments with LGE; 18 patients had enhancement only on dark-blood, 15 of them without known infarction, no histology. Fahmy: 45 patients, 5 swine; gray-blood detected more scarsNeeds a T1 map; two delays plus effective TE; may fail soon after injection; scar-to-myocardium contrast falls with black-blood settings
Magnetisation-transfer IR, FIDDLE (Kim 2018)Flow-independent dark-blood with magnetisation transfer22 canines against histology: sensitivity 96% vs 85%, accuracy 95% vs 87% for conventional LGE; 31 patientsScar-to-myocardium contrast −14% at 1.5 T and −10% at 3 T; more in-flow artefact at 3 T
TRAMINER (Muscogiuri 2017)Slice-selective and MT IR40 patients; contrast gain; two scars missed by conventional LGE; no difference in transmural extentNon-uniform RV and LV blood suppression; transmurality and microvascular obstruction may be underestimated
SIR-IR (Farrelly 2011)Saturation-inversion3 swine, 26 patients; scar-to-blood contrast +90%Infarct SNR −64%; flow-dependent, less reliable when LVEF is below 40%
Blood-nulled PSIR (Holtackers 2017, 2019, 2021; Foley 2019)Dedicated TI that nulls blood, PSIR reconstruction; no extra preparation300 patients: 8 of 97 patients with ischaemic scar (8.3%) were missed by conventional LGE and scar burden rose 10%; porcine histology: bias −1.57% (conventional) vs −0.03% (dark-blood)Blood is dark-gray, not black; blood and scar cannot be separated if T1 is identical; myocardium-to-blood contrast falls

These figures are reported by one review that sums up single-centre studies; there is no pooled analysis and no cross-technique comparison [4]. The review also reports source inconsistencies (for example 12 versus 15 patients for one study) [4].

4.3 How Far the Evidence Goes

The authors conclude that dark-blood LGE is promising, that its superiority for subendocardial detection is already proven, that it may replace conventional LGE in specific settings such as myocardial infarction with non-obstructed coronary arteries (MINOCA), and that in generalised cardiomyopathy protocols it remains an addition to conventional LGE; for non-ischaemic scar its performance is largely unknown [4]. The SCMR protocol document lists it as optional and prefers flow-independent techniques for separating subendocardial LGE from the blood pool [1, 2]. Black-blood methods make thrombus as dark as blood and harder to detect; gray-blood methods keep thrombus visible but give lower scar-to-blood contrast [4]. Most techniques with extra preparation are not available in a commercial configuration, whereas blood-nulled approaches without extra preparation run on clinical systems [4]. Semi-automatic quantification of dark-blood LGE has not been validated against histology, and 3 T data are limited for many methods [4].

(Reasoning) A pragmatic use follows from this: bright-blood PSIR remains the base sequence; a dark-blood series is justified when subendocardial scar is the question and the bright-blood images are equivocal, and the series is read together with the conventional one, not instead of it.

5. Interpretation by Pattern and Extent

5.1 Pattern Reading

The SCMR post-processing document distinguishes a coronary-type pattern, which involves the subendocardium in a coronary territory, from a non-coronary pattern, which usually spares the subendocardium and is mid-wall or epicardial [2]. A narrative review lists the distributions typical of individual diseases [5].

DistributionDiseases linked to it in the reviewSource
Subendocardial or transmural, in a coronary territoryIschaemic cardiomyopathy and infarction[2, 5]
Mid-wall (striated or patchy)Dilated cardiomyopathy (often absent; when present, correlated with intraventricular conduction disturbance); Anderson-Fabry disease (infero-lateral mid-basal wall)[5]
SubepicardialMyocarditis (especially the postero-lateral wall); sarcoidosis (nodular, circumferential, subepicardial and subendocardial forms)[5]
Right-ventricular insertion pointsHypertrophic cardiomyopathy (anterior and posterior insertion points); systemic sclerosis (basal to mid septum and insertion points)[5]
Diffuse, widespreadEnd-stage hypertrophic cardiomyopathy[5]
Subendocardial, global, with mid-septal sparingEarly cardiac amyloidosis (later more homogeneous)[5]
Transient, patchy, low intensityStress (Takotsubo) cardiomyopathy[5]

The review is narrative, dates from 2014, and mixes studies of different size and design; the associations are patterns, not diagnostic rules, and a diffuse type of fibrosis may be missed by LGE (T1 mapping and ECV are the proposed complement) [5]. The 2018 expert panel adds that, in suspected myocarditis, LGE alone is not recommended for diagnosis and cannot separate recent from remote injury [3].

5.2 Transmurality and Viability

The post-processing document describes the average transmural extent per segment in bins of 0%, 1–25%, 26–50%, 51–75% and 76–100%, using the 17-segment model, and compares the LGE position with cine and perfusion images; in acute infarction, no-reflow zones are included in the infarct size [2]. The landmark study of reversible dysfunction found that the likelihood of improved contraction after revascularisation falls progressively as the transmural extent of hyperenhancement increases [8]; only the qualitative gradient is stated here, because the study was read at abstract level and the exact percentages should be taken from the original. Viability work-up as a whole belongs to the planned ischaemic child page.

6. Quantification

6.1 What the Consensus Says

For most clinical indications, visual assessment is sufficient, and quantification is described as mainly a research tool whose use still requires a visual read first [2]. The document gives these statements: manual planimetry is subjective; the n-SD technique has a recommended starting point of 5 SD for infarction, but there is not enough evidence to provide a cut-off for non-ischaemic LGE; the FWHM technique, which sets the threshold at half the maximal signal within the scar, is considered more reproducible but may be less accurate when enhancement is patchy or gray; grey-zone methods are not endorsed because of partial-volume effects; and the Task Force names no optimal method [2].

6.2 Comparative Data

Finding in a 60-patient study (20 acute infarction, 20 chronic infarction, 20 hypertrophic cardiomyopathy)Source
LGE volume differed significantly with the method used[6]
FWHM, manual, 5-SD and 6-SD gave no significant difference in mean volume[6]
2-SD gave volumes up to twice those of FWHM, 6-SD and manual methods[6]
Reproducibility was worse in hypertrophic cardiomyopathy than in infarction for all methods[6]
FWHM was the most reproducible method in all three conditions; the abstract states a sample-size reduction of at least 60% in one place and up to one-half in another[6]

The comparison used manual quantification as its reference, not histology, and was read at abstract level [6]. The practical consequence is that a scar mass or percentage of left-ventricular mass is meaningful only together with the method, the threshold and the sequence type, and cannot be compared between centres otherwise (Reasoning, from [2, 6]). The post-processing document also warns that windowing and quantification may behave differently on PSIR and magnitude images [2]. No reporting standard for scar as a percentage of left-ventricular mass is given [2].

7. Reporting Framework

ItemContent
TechniqueSequence type (PSIR or magnitude; segmented or single-shot; dark-blood if used), time after contrast, TI strategy, plane used to verify
PresencePresent or absent; confirmed in a second plane or after a change of readout direction
Location17-segment model; pattern (subendocardial, mid-wall, subepicardial, transmural, insertion points, diffuse)
ExtentTransmural bin per segment (0, 1–25, 26–50, 51–75, 76–100%)
Related findingsNo-reflow or thrombus (with long-TI image if acquired); correspondence with cine and perfusion findings
QuantificationIf given: method, threshold, software, and the statement that values are not interchangeable between methods
LimitationsArrhythmia, poor breath-hold, ghosting, uncertain TI, single-shot compromise

8. Technical Pitfalls

PitfallConsequenceSource
TI too short on magnitude images ("etched" normal myocardium)Underestimated LGE[2]
Magnitude image, tissue with long T1 below the zero crossingFalse appearance of enhancement[2]
Ghosting from poor gating, poor breath-hold or long-T1 fluidFalse enhancement or masked scar[2]
TI drift across a long stack on magnitude imagesSlice-dependent infarct size[7]
Severe microvascular obstruction on PSIRSign error (1 of 25 cases in the original study)[7]
No-reflow zone or mural thrombusHard to separate from viable myocardium; long-TI imaging, PSIR or post-contrast cine may help[2]
Bright-blood only, subendocardial scarScar mistaken for blood or the reverse[4]
Black-blood dark-blood LGEThrombus as dark as blood[4]
Quantification with a low n-SD thresholdVolumes up to twice those of other methods[6]

9. MRI Technologist Pearls and Quality Checklist

9.1 Pearls (Reasoning)

Run the LGE series in the same slice positions as cine so that a finding can be matched slice by slice. Look at the first image of each stack before continuing: a mismatch between nulled myocardium and a bright blood pool is easier to correct early than after the full stack. If an area of enhancement is doubtful, repeat that slice with the phase-encoding direction swapped before changing anything else. Record the TI and the time after contrast on the study so that the radiologist can state them in the report.

9.2 Quality Checklist

CheckPass criterion
NullingNormal myocardium uniformly dark; no etched appearance on magnitude images
GhostingNone crossing the myocardium; if present, repeated with changed readout direction or single-shot
CoverageSame views and slice positions as cine
TimingAt least 10 min after contrast (shorter with lower doses), recorded
ConfirmationEach enhancement seen in a second plane or after readout change
Subendocardial questionDark-blood or short-TI PSIR added when bright-blood images are equivocal
Thrombus or no-reflow questionLong-TI image added

10. Advanced Technical Parameters

ParameterValue statedSourceNote
TI scout versus segmented sequenceMay differ by up to 50 ms[1]Already on the master
Long-TI imaging (LGE section)About 550 ms at 1.5 T, 850 ms at 3 T[1]No-reflow, thrombus
Thrombus nulling (masses section)500–550 ms at 1.5 T, 850–900 ms at 3 T[1]As rendered by the tool
Short-TI PSIRAbout 200 ms[1]Subendocardial scar
Numerical nulling TI for normal myocardiumNot stated[1]Gap
3D LGE resolution, slice, timingNot stated[1]Gap
Original PSIR parameters (2002, 1.5 T)TR 7.8 ms, TE 3.4 ms, 8 mm slices, 1.4 × 2.8 mm in-plane, 96 phase encodes over 12 heartbeats, 5° reference flip angle, 20° IR[7]Historical; not a current recommendation
Contrast dose in the original study0.2 mmol/kg (double dose) or two single doses, 10–30 min after injection[7]Not a current dose recommendation
n-SD starting point for infarction5 SD[2]No cut-off for non-ischaemic LGE
FWHMHalf the maximal signal within the scar[2]No numerical cut-off

11. Evidence Gaps and Ongoing Debate

Numerical nulling TI and 3D parameters are not in the consensus text read (to be sourced). Diagnostic accuracy of dark-blood LGE for non-ischaemic scar is not established, and there are no outcome data for dark-blood methods [4]. Threshold choice: no cut-off is available for non-ischaemic LGE [2], and the best-performing method (FWHM) was compared against manual quantification, not histology [6]. Grey zone: not endorsed by the Task Force [2]. Pattern-based diagnosis: the evidence is a narrative review [5]; the performance of individual patterns in current cohorts was not examined here (to be sourced). Not read: the full text of Kim 2000 and Flett 2011, the 2018 expert panel beyond the points cited, MESA-type quantification studies and studies on prognosis of scar burden. Detail to be checked in the original: all values quoted from the two consensus documents and from the dark-blood review were read as rendered by a summarising tool.

12. Evidence-Based References

References are ordered by level of evidence and then by recency. The reading level of each source is stated in its line; a source read only at abstract level supports only what its abstract states.

A. Guidelines / Consensus / Society Recommendations

High
[1] Kramer CM, Barkhausen J, Bucciarelli-Ducci C, Flamm SD, Kim RJ, Nagel E. Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson. 2020;22:17. DOI: 10.1186/s12968-020-00607-1.
(High — Society consensus document; LGE sections read as rendered by a summarising tool, twice with consistent numerical statements; numerical values to be checked against the original) Cited in Sections 1, 2, 3, 4, 10, 11.
High
[2] Schulz-Menger J, et al. Standardized image interpretation and post-processing in cardiovascular magnetic resonance – 2020 update. J Cardiovasc Magn Reson. 2020;22:19. DOI: 10.1186/s12968-020-00610-6.
(High — Society consensus document; LGE section read as rendered by a summarising tool; numerical values to be checked against the original) Cited in Sections 1, 2, 3, 4, 5, 6, 8, 10, 11.
High
[3] Ferreira VM, Schulz-Menger J, Holmvang G, et al. Cardiovascular magnetic resonance in nonischemic myocardial inflammation: expert recommendations. J Am Coll Cardiol. 2018;72(24):3158–3176. DOI: 10.1016/j.jacc.2018.09.072. PMID: 30545455.
(High — Expert panel recommendations; partial reading, text truncated; cited only for the statement that LGE alone is not recommended for myocarditis and cannot separate recent from remote injury) Cited in Section 5.

B. Reviews

Moderate
[4] Holtackers RJ, et al. Dark-blood late gadolinium enhancement cardiovascular magnetic resonance for improved detection of subendocardial scar: a review of current techniques. J Cardiovasc Magn Reson. 2021;23:96. DOI: 10.1186/s12968-021-00777-6. PMID: 34289866.
(Moderate — Narrative review, not systematic, no pooled analysis; full text as rendered by a summarising tool; the review notes inconsistencies between its text and tables; several authors of the cited studies are also authors of the review, a possible source of bias) Cited in Sections 1, 2, 3, 4, 8, 11.
Limited
[5] Satoh H, Sano M, Suwa K, Saitoh T, Nobuhara M, Saotome M, Urushida T, Katoh H, Hayashi H. Distribution of late gadolinium enhancement in various types of cardiomyopathies: significance in differential diagnosis, clinical features and prognosis. World J Cardiol. 2014;6(7):585–601. DOI: 10.4330/wjc.v6.i7.585. PMID: 25068019.
(Limited — Narrative review of 2014; full text as rendered by a summarising tool; some statements on devices and contrast in the review are outdated and were not used) Cited in Section 5.

C. Important Prospective / Original Studies

Moderate
[6] Flett AS, Hasleton J, Cook C, Hausenloy D, Quarta G, Ariti C, Muthurangu V, Moon JC. Evaluation of techniques for the quantification of myocardial scar of differing etiology using cardiac magnetic resonance. JACC Cardiovasc Imaging. 2011;4(2):150–156. DOI: 10.1016/j.jcmg.2010.11.015.
(Moderate — Original study, 60 patients, reproducibility comparison; abstract/record level only; reference was manual quantification, not histology) Cited in Sections 1, 6, 8, 10, 11.

D. Technical MRI Papers

Technical
[7] Kellman P, Arai AE, McVeigh ER, Aletras AH. Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement. Magn Reson Med. 2002;47(2):372–383. DOI: 10.1002/mrm.10051. PMID: 11810682.
(Technical — Original technical study on a 1.5 T platform of one vendor; full text as rendered by a summarising tool; small samples, no histology, no sensitivity or specificity) Cited in Sections 1, 2, 8, 10.

E. Landmark Historical References

Moderate
[8] Kim RJ, Wu E, Rafael A, Chen EL, Parker MA, Simonetti O, Klocke FJ, Bonow RO, Judd RM. The use of contrast-enhanced magnetic resonance imaging to identify reversible myocardial dysfunction. N Engl J Med. 2000;343(20):1445–1453. DOI: 10.1056/NEJM200011163432003. PMID: 11078769.
(Moderate — Landmark prospective study; abstract only; used for the qualitative gradient between transmural extent and recovery; percentages to be taken from the original) Cited in Section 5.

Recent PubMed search for this protocol

Last updated: November 2026

Report an error on this page