Patient Planes, Orientation and Positions in MRI — Anatomical Planes, the DICOM Patient Coordinate System, Oblique Prescription and Patient Position Codes
MRIninja Knowledge Base | Foundations — Geometry and Positioning Parent page: MRI Physics — Fundamentals and Principles (9201) Related pages: Field of View · Acquisition Matrix · Slice Thickness · Magnetic Field, Hardware and Homogeneity Version 1.1 — November 2026
Foundations — Geometry and Positioning
Patient Planes, Orientation and Positions in MRI
Reference page on the anatomical reference planes, the patient-based coordinate system defined in the DICOM standard, oblique and double-oblique slice orientation, and the coded patient positions, with simplified diagrams. Laser localisation and the scanner coordinate system are treated on a separate page.
1. Scope, Boundary and Information Status
This page defines the vocabulary used on every protocol page to say where a slice is and how the patient lies: anatomical planes, patient axes, orientation of an image in the patient, and the position of the patient relative to the equipment. It does not describe laser alignment, landmarking, table movement or the scanner’s own coordinate axes (planned separate page, Section 11), nor receiver coils or the magnet.
Information status. The only sources actually read are parts of the DICOM standard (Section 12), and each was read through a tool that returns a model-written summary of the page, not the raw page text; the list of defined terms for Patient Position was read on a secondary website that reproduces the standard. No textbook, anatomical terminology source, society guideline or manufacturer documentation was read. Therefore: (a) statements that are definitions or geometry of the DICOM attributes are tied to citations; (b) statements derived by calculation from those definitions are marked (Reasoning); (c) general anatomical terminology, display conventions and practice are marked (to be sourced).
| Topic | Source status | Reading level |
|---|---|---|
| Patient-based coordinate system, Image Position (Patient), Image Orientation (Patient) | DICOM PS3.3 C.7.6.2 [1] | Page read through a summarising tool; the page does not state the Patient Position attribute |
| Patient Position defined terms (16 codes) | DICOM PS3.3 C.7.3.1.1.2, as reproduced on a secondary website [3] | Secondary copy; the official section page was not reachable |
| Relation between Patient Position and Patient Orientation sequences | DICOM PS3.3 section 10.12 [2]; C.8.11.5 [4] | Pages read through a summarising tool |
| Anatomical terminology, radiological display convention, practice by region | Not read | (to be sourced) |
2. Three Frames of Reference
Three distinct frames are used and must not be mixed (Reasoning):
| Frame | Defined by | Used for | Source |
|---|---|---|---|
| Patient (anatomical) frame | The patient’s own anatomy: left–right, anterior–posterior, superior–inferior | Naming planes (axial, coronal, sagittal) and describing findings | Section 3; terminology (to be sourced) |
| DICOM patient-based coordinate system | A right-handed system attached to the patient: x toward the patient’s left, y toward posterior, z toward the head, in mm | Image Position (Patient) and Image Orientation (Patient) of every image | [1] |
| Equipment (scanner) frame | Axes fixed to the magnet and table | Table travel, isocentre, slice offsets; the relation to the patient frame depends on how the patient lies (Section 6) | Not read; separate page (to be sourced) |
3. Anatomical Directions and the Three Cardinal Planes
3.1 Directions
| Term | Meaning | Status |
|---|---|---|
| Anterior (ventral) / posterior (dorsal) | Toward the front / back of the body | Standard anatomical terminology, source not read (to be sourced) |
| Superior (cranial) / inferior (caudal) | Toward the head / toward the feet | Same |
| Left / right | The patient’s own left and right, not the observer’s | Same |
| Medial / lateral | Toward / away from the median plane | Same |
3.2 Planes
| Plane | Normal (perpendicular) direction | Separates | Notes |
|---|---|---|---|
| Axial (transverse) | Cranio-caudal (z) | Upper from lower | Slices stacked head to foot (Reasoning) |
| Coronal | Antero-posterior (y) | Front from back | Slices stacked front to back (Reasoning) |
| Sagittal | Left–right (x) | Left from right | Slices stacked right to left or left to right (Reasoning) |
The three planes are mutually perpendicular. In practice an acquisition plane is called axial, coronal or sagittal when its normal is aligned with, or closest to, the corresponding axis; the rule used by individual systems to name an oblique plane was not read (to be sourced).
4. The DICOM Patient-Based Coordinate System
4.1 Definition
The Image Plane Module describes the geometry of each image in a patient-based, right-handed coordinate system in which, by default (Anatomical Orientation Type absent or BIPED), x increases toward the patient’s left, y toward the patient’s posterior and z toward the patient’s head; a different set of axes is defined for QUADRUPED [1]. Positions are expressed in millimetres [1].
| Attribute | What it gives | Notes |
|---|---|---|
| Image Position (Patient) (0020,0032) | x, y, z in mm of the upper-left corner of the image, i.e. the centre of the first transmitted voxel [1] | Origin of the image in the patient-based system |
| Image Orientation (Patient) (0020,0037) | Direction cosines of the first row and of the first column relative to the patient: six numbers, the row vector then the column vector [1] | The two vectors are orthogonal (zero dot product) and normalised (unit length) [1] |
| Pixel Spacing, Slice Thickness, Spacing Between Slices | In mm [1] | Used with the vectors above to map pixel indices to patient coordinates [1] |
| Slice Location (0020,1041) | Relative to an unspecified, implementation-specific reference point [1] | Not a patient coordinate; should not be used as one |
A note in the standard states that when the patient lies face up with head-to-foot aligned with the equipment’s front-to-back direction, the patient-based axes and the older equipment-based axes coincide [1]. The mapping of pixel indices to patient coordinates uses equations C.7.6.2.1-1 and -2 of the standard [1].
4.2 Direction Cosines of the Three Cardinal Planes (derived)
Using the axis definitions in 4.1, the usual pure-plane values can be written by calculation (Reasoning). The normal of the image is the cross product of the row and column vectors (row × column); the table gives it for each plane. These are the values obtained when the rows run along the stated axis; other row/column choices are possible and are valid if orthonormal.
| Plane | Row vector (first row direction) | Column vector (first column direction) | Normal = row × column | Slice normal points toward |
|---|---|---|---|---|
| Axial | (1, 0, 0) → patient left | (0, 1, 0) → posterior | (0, 0, 1) | head |
| Coronal | (1, 0, 0) → patient left | (0, 0, −1) → feet | (0, 1, 0) | posterior |
| Sagittal | (0, 1, 0) → posterior | (0, 0, −1) → feet | (−1, 0, 0) | patient right |
Reading the table (Reasoning): in an axial image with these vectors, pixel columns advance toward the patient’s left along each row and rows advance toward posterior down the image; the normal points toward the head, so consecutive slices acquired in increasing Image Position z run toward the head. How the viewer arranges these on screen is a display convention, not part of the vectors (Section 8).
5. Oblique and Double-Oblique Orientation
Because Image Orientation (Patient) holds two arbitrary unit vectors that are mutually orthogonal [1], any rotated plane can be written without a special case (Reasoning). A plane tilted about one patient axis is single oblique; a plane tilted about two axes is double oblique (Reasoning).
| Case | Row vector | Column vector | Constraint | Status |
|---|---|---|---|---|
| Axial plane rotated by θ about z (z positive toward head, angle measured from +x toward +y) | (cos θ, sin θ, 0) | (−sin θ, cos θ, 0) | Orthonormal for any θ | Calculation (Reasoning) |
| Coronal plane rotated by φ about y | (cos φ, 0, sin φ) up to the sign convention chosen | (0, 0, −1) rotated accordingly | Must remain orthogonal and unit length | Sign of the angle depends on the convention used; not defined by [1] (to be sourced) |
| General (double oblique) | Any unit vector r | Any unit vector c with r · c = 0 | Normal n = r × c | [1] for the constraints |
Consequences (Reasoning): (1) the normal of an oblique plane has non-zero components on more than one patient axis; (2) the plane of an oblique acquisition is therefore usually labelled by the nearest cardinal plane, and the label is a convention that can differ between systems and sites (to be sourced); (3) phase- and frequency-encode directions are defined in the slice-prescription frame of the system, so they rotate with the plane and are not given by the three cardinal axes alone (see Field of View and Acquisition Matrix pages for the geometry of the in-plane directions); (4) angulation angles quoted in protocols have no meaning without the rotation axis, the reference plane and the sign convention, none of which is fixed by the DICOM vectors.
6. Patient Position
6.1 Meaning and Role of the Attribute
Patient Position (0018,5100) specifies the position of the patient relative to the imaging equipment space; it is for annotation only and does not give an exact mathematical relationship between the patient and the equipment [3]. When the Patient Orientation Code Sequence is present, it gives a more precise statement of the position, and Patient Position is then not used [2]. If Patient Position is present in the DX positioning module, it shall be consistent with the Patient Gantry Relationship and Orientation Modifier sequences [4]. The CT section of the standard lists examples (conventional CT: HFS; dedicated breast CT: AFP; standing and seated CT: HFV, a code for upright positions) [5]; the list for MRI was not found in the sources read (to be sourced).
6.2 Defined Terms
Each code combines which part of the patient enters the equipment first with which body surface faces down [3]. The expansions below are those given by the standard [3]; the plain-language meaning in the third column is a reading of the terms (Reasoning).
| Code | Standard expansion [3] | Plain meaning |
|---|---|---|
| HFS | Head First–Supine | Head enters first; lying on the back (Reasoning) |
| HFP | Head First–Prone | Head enters first; lying face down (Reasoning) |
| HFDR | Head First–Decubitus Right | Head enters first; lying on the right side (Reasoning) |
| HFDL | Head First–Decubitus Left | Head enters first; lying on the left side (Reasoning) |
| FFS | Feet First–Supine | Feet enter first; lying on the back (Reasoning) |
| FFP | Feet First–Prone | Feet enter first; lying face down (Reasoning) |
| FFDR | Feet First–Decubitus Right | Feet enter first; lying on the right side (Reasoning) |
| FFDL | Feet First–Decubitus Left | Feet enter first; lying on the left side (Reasoning) |
| LFS | Left First–Supine | Left side enters first; lying on the back (Reasoning) |
| LFP | Left First–Prone | Left side enters first; lying face down (Reasoning) |
| RFS | Right First–Supine | Right side enters first; lying on the back (Reasoning) |
| RFP | Right First–Prone | Right side enters first; lying face down (Reasoning) |
| AFDR | Anterior First–Decubitus Right | Front of the body enters first; lying on the right side (Reasoning) |
| AFDL | Anterior First–Decubitus Left | Front of the body enters first; lying on the left side (Reasoning) |
| PFDR | Posterior First–Decubitus Right | Back of the body enters first; lying on the right side (Reasoning) |
| PFDL | Posterior First–Decubitus Left | Back of the body enters first; lying on the left side (Reasoning) |
6.3 Consequences of the Position for the Frames
For a given position, the three patient axes map to a different set of scanner axes: a change from head first to feet first reverses the direction of the cranio-caudal axis relative to the scanner, and a change from supine to prone reverses the anterior–posterior axis relative to the table and, with it, the left-right axis relative to the observer standing at the foot of the table (Reasoning). The system uses the position entered at registration to write patient orientation and to label images; whether and how a given system uses the entered position to compute orientation is specific to the system (to be sourced).
| Change of position | Patient axis reversed relative to the equipment | Source |
|---|---|---|
| Head first ↔ feet first | Cranio-caudal (z) | (Reasoning) |
| Supine ↔ prone | Antero-posterior (y) and left-right (x) as seen by an observer at the foot end | (Reasoning) |
| Left ↔ right decubitus | Left-right relative to gravity and the table surface; the equipment-referenced left-right axis is not reversed | (Reasoning) |
7. Verification of Position and Orientation (Derived Checks)
Because the entered position drives the orientation labels, a mismatch between the entered and the actual position produces labels that are wrong in a consistent way (a head-first supine patient entered as feet-first supine would appear mirrored along the cranio-caudal and left-right axes in the coordinate mapping (Reasoning)). The following checks follow from the definitions above; no guideline on position verification was read (to be sourced).
| Check | Reason |
|---|---|
| Compare the entered Patient Position with how the patient actually lies, before the first sequence | The code encodes head/feet-first and body-surface down [3] |
| Check one image with a physical laterality marker or a known asymmetric structure | The vectors give geometry; display and label errors are detected only by inspection (Reasoning) |
| Do not infer laterality from the side of the screen on which an anatomical structure appears | Display convention is separate from the vectors (Section 8) |
| After any change of position or table entry direction, repeat the localiser | New geometry; derived from Section 6.3 (Reasoning) |
| Record the position code in the examination documentation | Needed to interpret the geometry later; practice statement (to be sourced) |
8. Display Conventions Are Separate from Geometry
The Image Orientation (Patient) attribute describes the direction of rows and columns in the patient frame [1]; it does not say how an image is arranged on a screen. The conventional radiological display of an axial image (viewed from the feet, with the patient’s right on the observer’s left) is a display convention and was not read in the sources of this page (to be sourced). A viewer that follows the vectors can display any plane in a consistent way; a viewer that ignores them cannot, so oblique images must be read on software that honours the orientation attribute (Reasoning).
9. Position and Plane Choice by Region
The position, planes and angulations used for each region are stated on the regional protocol pages, and this page does not repeat them. Examples of a regional question that belongs to the child page and not here: whether a given region is examined prone or supine and why, the plane used for a specific measurement, and the angulation reference used for a given structure.
10. Evidence Gaps and Limits
(a) Anatomical terminology and radiological display conventions: no source read (to be sourced). (b) The official text of C.7.3.1.1.2 (Patient Position) was not read; the defined terms come from a secondary website [3]. (c) The MRI-specific list of positions and their frequency of use: none read (to be sourced). (d) Naming and angle conventions of oblique prescription by system: not read (to be sourced). (e) The DICOM pages were read through a summarising tool, so the wording quoted from them is a paraphrase; the primary page should be consulted before any formal use. (f) The three diagrams are constructed schematics, not measurements.
11. Planned Related Pages (Not Yet Published)
Published: Laser Positioning, Landmarking, Isocentre and the Scanner Coordinate System (laser light, landmark, isocentre, table movement, offsets and positioning quality control). Planned, not yet written: (1) the numerical mapping between patient and scanner axes for each position; (2) macroscopic structure of the scanner and component pages (magnet, gradients, table, radiofrequency system); (3) radiofrequency coils: structure and characteristics by type. Until those pages exist, the equipment frame is described here only in Section 2.
12. Evidence-Based References
The standard is a technical specification, not a study; no EBM level applies. Every source is listed with the way it was read. Dated 2024c editions were used where the current edition page was not reachable.
A. Standards and Technical Specifications
B. Guidelines, Textbooks and Terminology Sources
None read for this page (to be sourced): anatomical terminology (Terminologia Anatomica), a radiological display convention source, and a textbook or guideline on patient positioning.
Related Protocols
Recent PubMed search for this protocol