MRI Small Bowel / MR Enterography – Generic Standard Protocol
Required Protocol at a Glance
Mandatory core sequences for this examination. Detailed rationale, conditional additions and optimisation notes are provided later in the protocol.
MRIninja Knowledge Base | Master / General Protocol Page
Related pages: Liver master (5101) · Biliary / MRCP master (5201) · Pancreas master (5301) (companions, not parents)
Version 1.0 — October 2026
1. Executive Summary
Magnetic resonance enterography (MRE) is cross-sectional imaging of the small bowel in which the lumen is distended with an orally ingested enteric contrast agent, bowel motion is reduced with an intravenous spasmolytic, and the examination combines T2-weighted, balanced steady-state free precession (SSFP) and, in most protocols, fat-suppressed T1-weighted sequences, with diffusion-weighted imaging (DWI) and cine motility as optional additions [1, 4, 7]. It is performed without ionising radiation. The ECCO-ESGAR guideline states that "due to the absence of radiation, MRI should be preferred over CT particularly in young patients", and that CT "should be used judiciously, ideally only in the emergency setting and if IUS and MRI are unavailable" [2].
The page describes the generic adult examination. It is built on the joint ESGAR/ESPR technical consensus [7], the SAR/AGA consensus on interpretation and reporting in small bowel Crohn's disease [6], the ECCO-ESGAR guideline and reporting review [2, 5] and the 2025 ESGAR practice recommendations [4]. Most of the evidence concerns Crohn's disease; for other indications the page says where evidence was not read (Section 2).
The question the examination answers is, in most patients, one of five: is there active small bowel inflammation, how extensive is it, is there a stricture and is it likely to need intervention, is there penetrating disease (fistula, sinus tract, abscess), and has treatment worked. In the one multicentre accuracy trial read (METRIC, 284 patients, panel-diagnosis reference standard), MRE had a per-patient sensitivity of 97% (95% CI 91–99) and specificity of 96% (86–99) for the presence of small bowel Crohn's disease, and a sensitivity of 80% (72–86) and specificity of 95% (85–98) for disease extent [12].
1.1 Core Strengths
No ionising radiation and repeatability: relevant because Crohn's disease is usually diagnosed in young patients and followed with repeated imaging [2].
Transmural and extramural assessment: the wall, the mesentery, lymph nodes, vasa recta, fistulae and abscesses are shown together, which endoscopy and capsule endoscopy cannot do [6, 2]. In METRIC, MRE was more accurate than small bowel ultrasonography for disease extent: sensitivity 80% versus 70% and specificity 95% versus 81% [12]; the 2025 ESGAR recommendations draw the conclusion that MRE is usually preferred over intestinal ultrasound for staging at diagnosis [4].
Comparable to CT enterography for activity: a meta-analysis of six studies (290 patients) found pooled sensitivity 87.9% (95% CI 81.8–92.5) and specificity 81.2% (71.9–88.4) for MRE and 85.8% (79.2–90.9) and 83.6% (75.3–90.1) for CT enterography, with no statistically significant difference in incremental yield [11]. Only the abstract of this review was read.
Treatment response: MRE and intestinal ultrasound "appear to be of similar value for monitoring transmural healing" [2]; the SAR/AGA panel made a weak recommendation that MRE be used rather than CT enterography when possible to estimate response to medical treatment [6].
1.2 Intrinsic Limitations of the Generic Protocol
It is a long, demanding examination for the patient: fasting for 4–6 h, ingestion of 1,000–1,500 ml of contrast over 46–60 min and a scan time that should in general not exceed 30 min [7]. In the METRIC observational analysis, 27% (12/45) of patients given PEG and 44% (37/84) given mannitol rated the feeling of fullness "very tolerable" [14].
Motion and distension determine image quality: collapsed or poorly distended segments simulate wall thickening; the ECCO-ESGAR reporting review states that non-distended bowel may overestimate inflammation and that the 3 mm wall thickness cut-off applies to a distended segment [5].
It does not see everything: "MR enterography is not suitable for early recognition of recurrence, because aphthoid ulcers cannot be assessed" [2]; colonic disease is detected less accurately than by endoscopy [5, 6]; and "no imaging modality can fully assess whether a stricture is inflammatory or fibrotic in nature" [2] (see Section 11 for the more optimistic meta-analytic data).
The evidence base is dominated by Crohn's disease and by expert consensus: most technical statements are graded level V (expert opinion) in the source [7]. Where this page adds an interpretation that no source states, it is marked Reasoning; where no source was read, it is marked (to be sourced).
1.3 Evidence Base and Its Reading Level
| Source | Type | Reading level | Used for |
|---|---|---|---|
| ESGAR/ESPR joint consensus 2017 [7] | Delphi consensus, 13 experts, 157 statements (129 [82%] immediate consensus, 19 [12%] after modification, 9 [6%] rejected) | Full text read | Preparation, spasmolytic, contrast, sequences, thickness, timing |
| SAR/AGA consensus 2018 [6] | Panel consensus (24 members) | Pre-publication manuscript read; page numbers absent, cited by table and recommendation | Findings, definitions, reporting |
| ECCO-ESGAR guideline 2018 [2] | Guideline | Accepted manuscript read (not journal pagination) | Indications, modality comparison, monitoring |
| ECCO-ESGAR reporting review 2021 [5] | Topical review with practice positions | Accepted manuscript read | Reporting items |
| ESGAR practice recommendations 2025 [4] | Invited review; no consensus method described | Accepted manuscript read | Minimum sequences, scores, stricture criteria |
| ECCO-ESGAR-ESP-IBUS guideline 2025, Part 2 [1] | Guideline | Abstract and record only; full text restricted and not read | Declared as a gap |
| ACR Appropriateness Criteria Crohn Disease [3] | Guideline (2015 version) | Abstract only; ratings not read | Declared as a gap |
| Systematic reviews and trials [8–15] | See Section 12 | Abstracts read for [8, 9, 11, 12, 14, 15]; full text for [13]; citation only for [10] | Accuracy, strictures, spasmolytics, oral contrast |
| Product information [16, 17] | UK SmPC; US label | Read | Spasmolytic contraindications and doses |
Not available for this page: the ACR practice parameter for MR enterography (the document retrieved was the abdominal MRI parameter, revision 2026, of which only headings and references could be read), the paediatric ECCO-ESGAR-ESPGHAN-IBUS guideline, the full text of the original MaRIA and simplified MaRIA publications, and any society document on small bowel tumours or on coeliac disease.
2. Main Clinical Indications
2.1 Standard Indications
| Indication | What the source states | Source and grade |
|---|---|---|
| Suspected Crohn's disease with normal endoscopy | Small bowel capsule endoscopy or cross-sectional imaging should be considered | ECCO-ESGAR statement 1.8, EL2 [2] |
| Small bowel assessment at diagnosis of Crohn's disease | "All newly diagnosed CD patients should undergo small-bowel assessment" (intestinal ultrasound, MR enterography and/or capsule endoscopy). MRE is usually preferred over ultrasound for staging at diagnosis | Statement 1.10, EL2 [2]; ESGAR 2025 practice recommendation [4] |
| Symptomatic small bowel disease | May be investigated with MRE, intestinal ultrasound and/or capsule endoscopy; first-line choice depends on local availability and expertise | Statement 2.3.4, EL2 [2] |
| Relapse | Endoscopic or cross-sectional reassessment should be considered | Statement 2.1.2.2, EL5 [2] |
| Extramural complications (fistula, abscess) | Should be monitored by cross-sectional imaging, ultrasound or MRI or both | Statement 2.1.2.4, EL2 [2] |
| Strictures and penetrating disease | Report presence, number, location, length, upstream dilation and whether inflammation is present within the stricture | SAR/AGA strong recommendations [6] |
| Response to treatment | MRE and intestinal ultrasound similar for transmural healing; MRE preferred to CT enterography when possible | ECCO-ESGAR text [2]; SAR/AGA Rec. 8, weak [6] |
| Small intestinal tumours | MRE pooled sensitivity 0.92 (95% CI 0.89–0.95) and specificity 0.81 (0.74–0.86); CT enterography 0.93 (0.90–0.95) and 0.83 (0.76–0.88); 8 articles, 551 cases | Meta-analysis, abstract read [9] |
| Suspected chronic gastrointestinal bleeding | The ESGAR/ESPR consensus lists arterial (30 s), enteric (45 s) and portal venous (70 s) phases as options for the contrast-enhanced sequences. No source on diagnostic accuracy or on the place of MRE in the bleeding work-up was read | Technical statement [7]; clinical role (to be sourced) |
| Coeliac disease, other small bowel disorders, paediatric indications | No source read for this page | (to be sourced) |
Where MRE is not the first choice: the ECCO-ESGAR guideline states that colonoscopy is the modality of choice for colonic disease activity, with cross-sectional imaging complementary for phenotype [2]. A dedicated pelvic MRI perianal fistula protocol is required for pre-operative perianal assessment (SAR/AGA Rec. 6, strong), although every enterography examination should image the anus [6]. Both are outside this page (see Related Content).
2.2 Urgent Red Flags Requiring Expedited or Emergency Imaging
The ECCO-ESGAR guideline limits CT to the emergency setting when intestinal ultrasound and MRI are unavailable [2]. The ECCO-ESGAR reporting review states that free perforation must be communicated immediately and that abscess dimensions and the feasibility of drainage should be reported [5].
Reasoning: the examination requires ingestion of about 1 litre of fluid over an hour and 30 minutes or more on the table, so it is poorly suited to a patient who is acutely unwell with suspected perforation or complete obstruction. No source read for this page states a contraindication of MRE for these conditions or how the oral load should be modified in high-grade obstruction (to be sourced); the decision rests with the referring clinician and the radiologist.
3. Preparation Reference
Universal screening (implants, devices, pregnancy, renal function, claustrophobia, gadolinium history) is covered in Universal MRI Preparation and in MRI Safety Master (9800); this section lists only what is specific to enterography.
3.1 Anatomy-Specific Preparation Items
| Item | Recommendation | Source and grade |
|---|---|---|
| Solid food | None for 4–6 h | ESGAR/ESPR, V [7] |
| Fluids | None for 4–6 h; non-sparkling water permissible. Sparkling water is not recommended (Discussion) | V [7] |
| Routine medication | Do not stop | V [7] |
| Bowel cleansing | Laxative preparation not recommended; routine rectal water enema not recommended | V [7] |
| Oral enteric contrast, agent | No single preferred agent. Options include mannitol (with or without locust bean gum), polyethylene glycol (PEG), sorbitol and lactulose | III [7] |
| Oral enteric contrast, volume | Optimal 1,000–1,500 ml; no consensus on a minimum volume. The discussion cites a volunteer study in which less than 1,000 ml gave inferior distension and states that about 450 ml can give acceptable images | III [7] |
| Oral enteric contrast, timing | Ingest over 46–60 min (as printed in the source) before the examination, in patients without previous major small bowel resection. After major resection the discussion suggests scanning earlier, for example at about 30 min, which is not a consensus statement | V [7] |
| Splitting the dose in two | No consensus: the statement that splitting into two aliquots is not recommended failed to reach consensus; the discussion considers both single and split approaches acceptable | V [7] |
| Stoma | Plug the stoma before oral contrast ingestion | V [7] |
| Intravenous access | Needed for the spasmolytic and for gadolinium (Sections 3.3 and 6) | [7] |
| Documentation | Record fasting period, oral contrast volume ingested, bowel distension (optimal, suboptimal, insufficient), antiperistaltic drug with dose and route, scan coverage | ECCO-ESGAR reporting review, Table 1 [5] |
The reporting table of the ECCO-ESGAR review prints "minimum 500 ml" next to the oral contrast volume field [5], whereas the ESGAR/ESPR panel did not reach consensus on a minimum volume [7]. The text read does not explain the figure; treat 1,000–1,500 ml as the consensus target and do not read 500 ml as a validated lower limit.
Reasoning (patient information, not source-based): explain before the first cup that the drink is large and may cause fullness, nausea or loose stools, and agree how the patient will signal vomiting or urgency; no source read tests the wording of patient instructions (to be sourced).
3.2 Patient Positioning on the MRI System
Prone and supine positioning are both acceptable (III) [7]. Phased-array coils are mandatory (V), and scan coverage should include at least the small bowel and the colon, extended to the perineum (V) [7]. The SAR/AGA panel notes that artefacts often occur over the anus because of the position of the external phased-array coils and that adequate anal imaging can be achieved with the body coil [6]. Which position gives better distension or tolerance was not found in the sources read (to be sourced).
3.3 Spasmolytic (Antiperistaltic) Agent
The ESGAR/ESPR consensus recommends a spasmolytic for MRE (II), intravenous hyoscine butylbromide as first line at 20 mg (V, III) and intravenous glucagon at 1 mg as second line if the first-line agent cannot be given (V) [7]. Timing should take account of the motion sensitivity of the sequences (V); the discussion recommends giving the agent before the T2-weighted and post-contrast T1-weighted sequences, accepts a single or a split dose, and records that a split-dose statement did not reach consensus [7]. The consensus statements do not list contraindications [7]; they are taken from the product information below.
| Hyoscine butylbromide | Glucagon | |
|---|---|---|
| Consensus dose, adults | 20 mg IV [7] | 1 mg IV [7] |
| Label dose (as read) | UK SmPC: 20 mg IM or IV, repeated after half an hour if necessary; IV slowly; maximum daily dose 100 mg; "not recommended for children" [16] | US label for diagnostic use: 0.2–0.5 mg IV (small bowel), 0.5–0.75 mg IV (colon), or 1 mg IM [17] |
| Onset and duration (label) | Not stated in the SmPC text read | IV 0.25–0.5 mg: onset 45 s, duration 9–17 min; IV 2 mg: onset 45 s, duration 22–25 min [17] |
| Contraindications (label) | Hypersensitivity; narrow-angle glaucoma; prostate hypertrophy with urinary retention; mechanical gastrointestinal stenosis, paralytic or obstructive ileus, megacolon; tachycardia; myasthenia gravis [16] | Hypersensitivity (glucagon, lactose or constituents); pheochromocytoma; insulinoma [17] |
| Warnings (label) | Can cause tachycardia, hypotension and anaphylaxis; raised intraocular pressure; caution with fever; caution when driving afterwards [16] | Caution in diabetes (hyperglycaemia), prolonged fasting, adrenal insufficiency, chronic hypoglycaemia and known cardiac disease [17] |
Discrepancies the reader should know: (i) the consensus glucagon dose (1 mg IV) is higher than the IV range printed in the US label for small bowel relaxation (0.2–0.5 mg) [7, 17]; (ii) the ESPR paediatric statement recommends hyoscine at 0.5 mg/kg IV, whereas the UK label states it is not recommended for children [7, 16]; (iii) the US label read is a 2018 version that "may not be the latest approved by FDA" [17]. Local drug policy and the product information in force at the site take precedence (to be sourced for each jurisdiction).
Comparative data: in a blinded crossover study of 10 healthy volunteers (1.5 T, oral preparation with a gadolinium-based agent and ispaghula), intravenous hyoscine butylbromide 40 mg arrested motion in 5 of 10 and glucagon 1 mg in 10 of 10 (p = 0.05); mean duration of aperistalsis until the first motion was 6.8 ± 5.3 min for hyoscine and 18.3 ± 7 min for glucagon (p < 0.0001), with onset about 22 s and 13 s [13]. Limits: 10 healthy volunteers, no patients, a hyoscine dose twice the consensus dose, only the intravenous route, and no reference method for motility [13]. Reasoning: with a mean arrest of about 7 min after hyoscine in this study, motion-sensitive sequences acquired late after the injection may be exposed to peristalsis again; whether this matters for image quality in patients was not found in the sources read (to be sourced).
Sources for Section 3: [5, 6, 7, 13, 16, 17].
4. Standard Protocol Design
Sequence names differ by vendor (SSFP is TrueFISP, FIESTA or balanced FFE; see bSSFP (9015)). The following protocol follows the ESGAR/ESPR statements [7] and states where later documents differ.
4.1 Mandatory Core Sequences
| # | Sequence | Plane | Status and limit | Source |
|---|---|---|---|---|
| 1 | FSE T2-weighted, no fat suppression (2D preferred; 3D allowed) | Axial and coronal | Recommended; maximum slice thickness 5 mm | V [7] |
| 2 | SSFP gradient echo, no fat suppression | Axial and coronal | Recommended; maximum slice thickness 5 mm | V [7] |
| 3 | FSE T2-weighted with fat suppression | Axial or coronal | Recommended | V [7] |
| 4 | T1-weighted fat-suppressed 3D, before contrast | Coronal first | Recommended in the ESGAR/ESPR consensus; maximum slice thickness 3 mm | V [7] |
| 5 | T1-weighted fat-suppressed 3D, after gadolinium | Coronal and axial | Recommended in the ESGAR/ESPR consensus; maximum slice thickness 3 mm | V [7] |
Controversy on intravenous contrast: the 2025 ESGAR recommendations list as minimum sequences coronal SSFP, axial and coronal T2 FSE without fat suppression and axial or coronal T2 FSE with fat suppression, and present the pre- and post-contrast 3D T1 sequences, axial DWI (b 50 and 600) and coronal cine SSFP as optional, of which two of three should be added; they state that intravenous contrast is "not an essential standard MRE sequence" but helps to distinguish abscess from inflammatory pseudomass in penetrating disease [4]. The SAR/AGA panel made a weak recommendation that non-contrast MRE with T2 and DWI is an acceptable alternative when intravenous contrast cannot be given [6]. The three documents therefore do not give one answer on whether the post-contrast sequence is mandatory; the table above follows the 2017 consensus, and the choice should be written in the local protocol.
4.2 Conditional Sequences
| Sequence | Indication and status | Plane | Source |
|---|---|---|---|
| Diffusion-weighted imaging | Optional; free breathing; lower b-value 0 or 50, upper b-value 600–900; maximum slice thickness 5 mm. Routine axial DWI was not agreed. In the 2025 recommendations b 50 and 600 | Axial; coronal DWI not recommended | IV–V [7]; [4] |
| Cine motility (multiphase thick-slab SSFP) | Optional; routine use not agreed. Can display peristalsis and help to detect strictures | Coronal | V [7]; [6]; [4] |
| Additional FSE T2 with fat suppression, or SSFP with fat suppression | Optional | Axial or coronal | V [7] |
| Dynamic contrast-enhanced imaging | Not mandatory | — | V [7] |
| Magnetisation transfer | Not recommended | — | V [7] |
| Colonic distension with water enema | Only for dedicated colonic evaluation; water is the distension agent and the volume depends on tolerance; not routine | — | III, V [7] |
| MR enteroclysis (nasojejunal tube) | Not routinely recommended: "not significantly more sensitive or specific than MR enterography", less well tolerated, needs fluoroscopic tube placement. Consensus technique if used: 8–10 F tube, fluoroscopic placement, pump infusion 80–120 ml/min, MR fluoroscopic monitoring of filling | — | [2]; V [7] |
| Dedicated pelvic MRI for perianal fistula | Separate protocol when perianal disease is suspected (strong recommendation) | — | [6] |
Total acquisition time should in general be 30 min or less (V) [7].
4.3 Rationale Summary Per Sequence
| Sequence | What it is used to show | Source |
|---|---|---|
| T2 FSE without fat suppression | Lumen, wall thickness (measured in a distended segment on T2 or contrast-enhanced T1; 3 mm cut-off), mesenteric structures | [5] |
| T2 FSE with fat suppression | Increased T2 signal of the wall (oedema), "highly specific for disease activity"; fat suppression separates oedema from intramural fat | [4] |
| SSFP | Anatomy of lumen, wall and mesentery with short acquisition; multiphase thick-slab cine for peristalsis and strictures | [6, 7]. Reasoning: speed makes it less sensitive to bowel motion than longer sequences |
| T1 fat-suppressed 3D after gadolinium | Mural hyperenhancement and the comb sign (hypervascularity); abscess versus inflammatory pseudomass | [4] |
| DWI | Restricted diffusion as "supportive but a nonspecific sign of active inflammation"; fibrosis can also restrict diffusion; the diagnosis of active Crohn's disease "should not be made on the basis of restricted diffusion alone" | [5, 6, 4] |
4.4 Sequence Matching and Cross-Sequence Consistency
The consensus limits the slice thickness to 5 mm for T2 FSE, SSFP and DWI and to 3 mm for the 3D T1 sequences [7] (see Slice Thickness (9583)), and requires the same coverage on every sequence, from the small bowel and colon to the perineum [7]. The ESGAR/ESPR text does not specify TR, TE, flip angle, matrix or fat suppression technique [7]; these remain vendor- and site-specific (to be sourced). Reasoning: using the same field of view and table position for the coronal and axial series of a given weighting makes it easier to correlate a finding between planes; no source read tests this.
4.5 Fat Suppression — Region-Specific Technical Considerations
The consensus recommends one T2 FSE series with fat suppression and fat suppression on the T1 series; SSFP is recommended without fat suppression, and an additional SSFP series with fat suppression is optional [7]. Reasoning: gas and oral contrast in loops of bowel disturb the local field and can make frequency-selective fat suppression fail locally; the physics are in Chemical Shift and Fat–Water Physics (9206) and Physics of MRI Artefacts (9209). No source read quantifies this for enterography (to be sourced).
4.6 Slice Positioning — Complete Technical Reference
The sources read specify two things only: the planes (coronal and axial for the main series) and the coverage (at least small bowel and colon, extended to the perineum) [7]. The SAR/AGA text adds that every enterography examination should image the anus [6]. Angulation, field of view and the exact superior and inferior limits are not stated in the sources read (to be sourced). Reasoning: a coronal localiser and a coronal T2 series are used to plan the axial series so that the coverage can be checked before the contrast injection; this is a workflow suggestion and not a sourced requirement.
Sources for Section 4: [2, 4, 5, 6, 7].
5. Optimisation Strategy
5.1 Artefact Reduction by Source
| Source of degradation | Effect | Mitigation | Basis |
|---|---|---|---|
| Peristalsis | Blurring of the wall; pseudo-lesions | Intravenous spasmolytic given before the motion-sensitive sequences (T2-weighted and post-contrast T1-weighted); glucagon if hyoscine cannot be given | II, V [7] |
| Poor or uneven distension, especially jejunum | Collapsed loops simulate wall thickening; suboptimal distension is a cause of false-positive restricted diffusion | Respect the volume and ingestion window; measure wall thickness only in a distended segment; record distension as optimal, suboptimal or insufficient. In METRIC patients, jejunal distension was rated excellent or good in 40% (27/68) with mannitol and 14% (5/37) with PEG, the only significant difference between the agents | [5, 6, 7, 14] |
| Respiration | Misregistration between phases; blurring of DWI | DWI is acquired in free breathing, if performed. Reasoning: keep the post-contrast T1 series in a breath-hold with the same breathing instruction for every phase | IV [7]; Reasoning |
| Anal region | Artefact from the position of the external phased-array coil | Body coil can provide adequate anal imaging | [6] |
| Off-resonance banding in SSFP | Dark bands crossing the bowel and mesentery | Reasoning: see bSSFP (9015) and Physics of MRI Artefacts (9209) for the physics and the vendor-specific remedies; no source read tests remedies in enterography (to be sourced) | Reasoning |
| Susceptibility and distortion in EPI DWI | Distortion near gas and oral contrast | Reasoning: see EPI (9010), EPI-DWI (9014) and DWI (9012); no enterography-specific parameter set was found in the sources read (to be sourced) | Reasoning |
| Fat suppression failure | Residual fat signal; false T1 hyperintensity | Reasoning: see Chemical Shift and Fat–Water Physics (9206) | Reasoning |
5.2 Protocol Efficiency and Throughput
The consensus sets a general limit of 30 min for the total acquisition time in adults and 45 min in children [7]. Reasoning: the oral contrast ingestion (46–60 min) is not part of the acquisition time and adds to the time the patient spends in the department; whether ingestion in a waiting area is practicable depends on the department (to be sourced). Parallel imaging and acceleration are described in Parallel Imaging (9588); the sources read do not give acceleration factors for enterography (to be sourced).
5.3 Field Strength Considerations
"Both 1.5 and 3 T are adequate field strengths" (II); the statement that 1.5 T is optimal was deleted because consensus was not reached, and in the panel 11 of 13 members used 1.5 T routinely and 2 used 3 T [7]. Reasoning: at 3 T the SSFP banding and the higher SAR deposition need attention (bSSFP (9015), SAR and Bioeffects (9210)); no comparative image-quality study in enterography was read (to be sourced).
Sources for Section 5: [5, 6, 7, 14].
6. Contrast Use Principles Specific to Small Bowel MRI
This section covers the oral (enteric) agent and the intravenous gadolinium-based agent. The general properties of gadolinium agents are in Contrast Media in MRI (9101), and nephrogenic systemic fibrosis, retention, hypersensitivity and pregnancy in Gadolinium Contrast Agent Safety (9806).
6.1 Oral Enteric Contrast
The ESGAR/ESPR consensus names mannitol (with or without locust bean gum), PEG, sorbitol and lactulose as options, without ranking them (III), and does not classify them as mono- or biphasic [7]. The only comparison read is a retrospective observational analysis within the METRIC trial (105 patients scored for distension, 130 completing questionnaires) [14]:
| Outcome | Mannitol | PEG |
|---|---|---|
| Overall distension excellent or good | 54% (37/68) | 46% (17/37) |
| Jejunal distension excellent or good | 40% (27/68) | 14% (5/37) |
| Fullness "very tolerable" | 44% (37/84) | 27% (12/45) |
| Mannitol volume ≤1 l versus >1 l | No significant difference in distension or side effects | |
The abstract states that mannitol and PEG achieve broadly comparable distension and side-effect profiles, with better jejunal distension for mannitol [14]. The study is observational, so allocation to mannitol or PEG was not randomised; the volume comparison (≤1 l versus >1 l) concerns mannitol only; and the abstract reports 84 mannitol patients in the fullness comparison and 85 in the questionnaire group without explaining the difference [14]. Reasoning: mannitol, PEG and sorbitol act as osmotic agents that retain water in the lumen and appear bright on T2-weighted and dark on T1-weighted images; this physical rationale is general knowledge and was not tested in the sources read (to be sourced).
6.2 Gadolinium: Dose, Role and Alternatives
Dose and rate: intravenous gadolinium by pump injection at 2 ml/s and 0.1–0.2 mmol/kg in adults (V); 0.1 mmol/kg in children (V) [7].
Role: the 2025 ESGAR recommendations state that hypervascularity appears as mural hyperenhancement and the comb sign on post-contrast images, and that intravenous contrast helps to distinguish abscess from inflammatory pseudomass in penetrating disease [4]. The SAR/AGA panel accepts non-contrast MRE with T2 and DWI as an alternative when intravenous contrast cannot be given (Rec. 9, weak) [6].
6.3 Post-Contrast Acquisition Timing
| Context | Timing stated | Source |
|---|---|---|
| Known or suspected inflammatory bowel disease | Enteric phase (45 s) or portal venous phase (70 s) | ESGAR/ESPR, V [7] |
| Suspected chronic gastrointestinal bleeding | Arterial (30 s), enteric (45 s) or portal venous (70 s) | ESGAR/ESPR, V [7] |
| Crohn's disease, optional post-contrast 3D T1 | 60–70 s | ESGAR 2025 [4] |
| Sequence order | Non-enhanced coronal T1 with fat suppression first, then contrast-enhanced coronal and axial T1 with fat suppression | V [7] |
The 45 s and 70 s phases of the consensus and the 60–70 s window of the later recommendations overlap only at the portal venous phase; the documents do not discuss the difference. Which timing gives better lesion conspicuity in enterography was not found in the sources read (to be sourced).
6.4 Non-Contrast and Abbreviated Protocols
A non-contrast protocol of T2-weighted and diffusion-weighted imaging is accepted as an alternative by the SAR/AGA panel (weak) [6]. A systematic review and meta-analysis on abbreviated non-contrast MR enterography as an alternative to the full contrast-enhanced protocol was found in the search, but only its title was seen and its results were not read; its date and design are not verified (to be sourced).
Sources for Section 6: [4, 6, 7, 14].
7. Reporting Essentials
7.1 Interpretation Framework
| Finding | Definition or criterion as stated | Source |
|---|---|---|
| Wall thickening | 3 mm is the recommended cut-off for mural inflammation in small and large bowel, measured in a distended segment on T2 or contrast-enhanced T1. Grading in the SAR/AGA table: mild 3–5 mm, moderate 5–9 mm, severe ≥10 mm | [5]; [6] |
| Intramural oedema | Increased intramural T2 signal; "highly specific for disease activity" | [5, 4] |
| Ulcers | Small focal disruptions of the luminal surface of the distended bowel | [5] |
| Mural hyperenhancement | Reported qualitatively; stratified pattern; asymmetric involvement, especially along the mesenteric border, is described as specific for Crohn's disease; "mucosal hyperenhancement" is called an erroneous descriptor | [5, 6] |
| Grade of inflammation | Mild: segmental hyperenhancement with minimal wall thickening of 3–5 mm. Severe: ulcers or high T2 intramural signal. Hyperenhancement alone does not grade severity unless quantitative measures are used | [6] |
| Restricted diffusion | Supportive but a nonspecific sign; normal jejunum shows more non-focal restricted diffusion than normal ileum; fibrosis can also restrict diffusion | [5, 6, 4] |
| Comb sign | Engorged vasa recta supplying an inflamed loop; may be a marker of inflammation but may also reflect past inflammation | [6] |
| Perienteric and intramural fat | Perienteric oedema or inflammation in the adjacent mesenteric fat; intramural fat indicates chronicity and is unrelated to whether inflammation is present; fibrofatty proliferation ("creeping fat") | [6] |
| Lymph nodes | Adenopathy: short axis >1.5 cm; reactive nodes of 1–1.5 cm are considered normal in Crohn's disease | [6] |
| Stricture | "Small bowel segments with luminal narrowing and unequivocal proximal (upstream) dilation." Upstream lumen <3 cm none, 3–4 cm mild, >4 cm moderate to severe (Table 1). Fixed narrowing without dilation may be called a "probable stricture" only if confirmed by several sequences, fluoroscopy or serial examinations. Upstream dilatation ≥3 cm supports a stricture | [6]; [5] |
| Penetrating disease | Sinus tract, fistula, inflammatory mass, abscess, free perforation. Fistulae are described by the two structures they connect and as simple or complex; complex fistulae are often asterisk-shaped and tether loops. The term "phlegmon" should not be used. Perianal disease is not classed as penetrating disease | [6]; [5] |
| Mesenteric veins | Every examination should be evaluated for mesenteric venous thrombosis and varices (strong recommendation) | [6] |
Internal inconsistency in the SAR/AGA text: the introduction speaks of upstream dilation "often defined as >3 cm", Table 1 uses 3–4 cm for mild and >4 cm for moderate to severe, and Table 6 uses <4 cm for mild and ≥4 cm for moderate to severe [6]. State the threshold used in the report.
7.2 Mandatory Reporting Checklist
- [ ] Technical items: fasting period, oral contrast volume ingested, bowel distension (optimal, suboptimal, insufficient), antiperistaltic drug with dose and route, scan coverage, and the effect of any limitation on reader confidence [5]
- [ ] Inflammation: location and length of each involved segment; presence of inflammation within strictures and penetrating disease (strong) [6]
- [ ] Strictures: number, location, length, upstream dilation (strong) [6]
- [ ] Penetrating disease: type, connected structures, simple or complex; abscess dimensions and feasibility of drainage [5, 6]
- [ ] Mesenteric venous thrombosis and varices assessed (strong) [6]
- [ ] Anus imaged; dedicated pelvic MRI if perianal disease is suspected [6]
- [ ] Free perforation communicated immediately [5]
- [ ] Terms avoided: "phlegmon", "mucosal hyperenhancement"; "quiescent" and "chronic" are discouraged [6]
7.3 Structured Reporting, Activity Scores and Stricture Criteria
The SAR/AGA panel proposes impression categories: non-specific inflammation; active inflammatory Crohn's disease with or without luminal narrowing; Crohn's disease with no active signs; stricture with or without active inflammation; penetrating disease; perianal disease; other complications; and a structured template (Table 6) [6]. The ECCO-ESGAR review lists the items to be included in structured reports [5].
| Score or criterion | What was read | Source and level |
|---|---|---|
| MaRIA | Described as the first and best-validated MRE activity score; the London, extended London and Clermont scores differ in whether they need intravenous contrast or DWI. The thresholds of MaRIA were not read (to be sourced) | [4], expert recommendation |
| Simplified MaRIA (sMaRIA) | Four features: wall thickening >3 mm, mural oedema, perienteric fat stranding, ulcers (relative contrast enhancement and lymph node assessment dropped). Reported threshold ≥1 for active disease: sensitivity 90%, specificity 81%, AUROC 0.91; ≥2 for severe disease: 85%, 92%, 0.94. Derivation 98 patients, validation 37, single centre | [18], secondary news report of a conference presentation; the original paper was not read |
| MaRIA, sMaRIA and Nancy compared | Retrospective, 67 patients, 343 segments (109 [31.8%] active at ileocolonoscopy, reference SES-CD). AUC for active disease: MaRIA 0.752, sMaRIA 0.764, Nancy 0.765. Cut-off values were not reported in the abstract | [15], abstract only, retrospective single study |
| Stricture criteria (MRE) | Wall thickening >25%, luminal narrowing >50%, pre-stenotic dilation >3 cm; stricture length >5 cm favours surgery or stricturoplasty over endoscopic dilation. The primary source of these criteria was not read | [4], expert recommendation |
The SAR/AGA text states that validated imaging criteria for fibrosis were "currently being developed and evaluated" and gives no standardized quantitative activity index [6]; the later documents describe scores [4] and a meta-analysis on fibrosis [8] (Section 11).
7.4 Incidental Findings — Clinical Decision Framework
No source read for this page addresses the management of incidental findings at MR enterography (to be sourced). Findings outside the bowel in the upper abdomen and pelvis are interpreted with the criteria of the corresponding master pages (Liver master (5101), Biliary / MRCP master (5201), Pancreas master (5301), Female pelvis master (6201)).
Sources for Section 7: [4, 5, 6, 15, 18].
8. MRI Technologist Pearls
Items marked Reasoning are workflow suggestions that no source read tests.
8.1 Sequence Order Logic
The consensus order for the T1 series is the non-enhanced coronal sequence first and then the post-contrast series [7], and the spasmolytic is given before the T2 and post-contrast T1 sequences [7]. Reasoning: place the sequences most degraded by peristalsis soon after the injection, because the mean duration of arrest was about 7 min after intravenous hyoscine 40 mg and about 18 min after glucagon 1 mg in healthy volunteers [13].
8.2 Positioning Tricks
Prone or supine is acceptable [7]. Reasoning: choose the position the patient can hold for the whole examination, fix the coil so that it covers from the upper abdomen to the pelvis, and check on the first coronal image that the coverage reaches the perineum [7].
8.3 Fast Salvage Protocol
| Situation | Option | Source |
|---|---|---|
| Hyoscine cannot be given | Glucagon 1 mg IV as second line | V [7] |
| Gadolinium cannot be given | T2-weighted and DWI non-contrast MRE (weak recommendation) | [6] |
| Time is limited | The consensus limit is 30 min in general. Which sequences to drop first is not stated; the 2025 minimum set is coronal SSFP, axial and coronal T2 without fat suppression and T2 with fat suppression | [7, 4] |
| Neither spasmolytic can be given | Reasoning: proceed, accept motion, document it in the report and give priority to fast sequences; no source read describes this situation (to be sourced) | Reasoning |
8.4 Common Avoidable Errors
Consequences in this table are Reasoning unless a source is cited in the same row.
| Error | Consequence | Prevention |
|---|---|---|
| Scanning before the oral contrast has been ingested over the recommended window, or scanning late | Poor distension of distal segments, or of the proximal bowel if too late | Time the ingestion (46–60 min); consider earlier scanning after major small bowel resection (discussion only) [7] |
| Stoma not plugged before ingestion | Contrast loss and poor distension | Plug the stoma first [7] |
| Sparkling water or laxative preparation | Gas in the lumen; unneeded preparation | Non-sparkling water only; no laxatives [7] |
| Spasmolytic injected too early or not repeated when the effect has ended | Peristalsis on later sequences | Give it before the T2 and post-contrast T1 sequences [7]; split dose was not agreed in the consensus [7] |
| Spasmolytic given without screening | Adverse effects in patients with glaucoma, tachycardia, urinary retention, myasthenia, or with pheochromocytoma or insulinoma for glucagon | Check the contraindications in Section 3.3 [16, 17] |
| Anus or perineum outside the coverage | Perianal disease missed | Coverage to the perineum [7]; image the anus, with the body coil if the surface coil artefact hides it [6] |
| Wall thickness measured in a collapsed segment | False diagnosis of inflammation | Measure only in distended bowel [5] |
| Missing documentation | Report cannot be judged for technical adequacy | Record fasting, oral volume, distension, spasmolytic dose and route [5] |
9. Quality Control Checklist
- [ ] Fasting 4–6 h confirmed; no laxative; stoma plugged if present [7]
- [ ] Oral contrast volume and ingestion time recorded (target 1,000–1,500 ml over 46–60 min) [7]
- [ ] Spasmolytic screened, given, dose and route recorded [5, 7, 16, 17]
- [ ] Coverage from small bowel and colon to the perineum on every series [7]
- [ ] T2 FSE and SSFP in axial and coronal planes, slice thickness ≤5 mm [7]
- [ ] T2 with fat suppression acquired [7]
- [ ] T1 3D with fat suppression, slice thickness ≤3 mm; pre-contrast coronal first [7]
- [ ] Post-contrast timing recorded (45 s or 70 s in the consensus; 60–70 s in the 2025 recommendations) [7, 4]
- [ ] DWI, if performed: free breathing, b-values stated, slice thickness ≤5 mm [7]
- [ ] Distension graded as optimal, suboptimal or insufficient [5]
- [ ] Total acquisition time recorded (general limit 30 min) [7]
- [ ] Gadolinium dose recorded (0.1–0.2 mmol/kg in the consensus) [7]
10. Advanced Technical Parameters
This section is intended for MRI technologists, protocol optimisation specialists and advanced technical review. Only parameters stated in the sources read are given as values. TR, TE, flip angle, matrix, echo train length, fat suppression technique and acceleration factors are vendor- and site-specific and were not found in the sources read (to be sourced).
10.1 T2-Weighted FSE Without and With Fat Suppression
Tissue Contrast Logic
Fluid in the distended lumen is bright on T2-weighted images and the bowel wall is intermediate to low in signal, so the wall is outlined by the lumen on one side and by mesenteric fat on the other. Fat suppression removes the signal of mesenteric and intramural fat so that oedema (increased T2 signal) can be separated from fat [4]. The sequence principles are in TSE/FSE (9005) and fat-water physics in Chemical Shift and Fat–Water Physics (9206).
Key Parameters
| Parameter | Value stated | Source |
|---|---|---|
| Planes | Axial and coronal without fat suppression; axial or coronal with fat suppression | V [7] |
| Dimension | 2D or 3D allowed, 2D preferred | V [7] |
| Maximum slice thickness | 5 mm | V [7] |
| Other parameters | Not specified | (to be sourced) |
Diagnostic Advantages
Shows wall thickness and intramural oedema; the increased T2 signal of the wall is described as highly specific for disease activity [4].
Limitations
Motion of the bowel degrades the images unless a spasmolytic is given [7]; non-distended segments give a false impression of thickening [5].
10.2 Balanced SSFP and Cine Motility
Tissue Contrast Logic
Balanced SSFP gives a contrast dependent on the T2/T1 ratio, bright for fluid, and is acquired rapidly; the physics, off-resonance banding and vendor names are in bSSFP (9015). Reasoning: this rapid acquisition explains why it is part of the core set for a moving organ, but no source read states this rationale for enterography.
Key Parameters
| Parameter | Value stated | Source |
|---|---|---|
| Planes | Axial and coronal, without fat suppression (additional series with fat suppression optional); the 2025 minimum set includes coronal SSFP | V [7]; [4] |
| Maximum slice thickness | 5 mm | V [7] |
| Cine motility | Optional; multiphase thick-slab acquisition (coronal cine SSFP in the 2025 recommendations); routine use not agreed | V [7]; [6]; [4] |
Diagnostic Advantages
Cine SSFP can display peristalsis and can help to detect strictures [6]; the 2025 recommendations state that cine MRI can quantify terminal ileal motility and that reduced motility correlates with histopathological and endoscopic activity in a multicentre prospective study cited there, which was not read [4].
Limitations
Routine use of cine motility did not reach consensus [7]. Banding artefacts are described in bSSFP (9015) and Physics of MRI Artefacts (9209).
10.3 Diffusion-Weighted Imaging in Enterography
| Parameter | Value stated | Source |
|---|---|---|
| Status | Optional; routine axial DWI was not agreed | V [7] |
| Breathing | Free breathing | IV [7] |
| b-values | Lower 0 or 50; upper 600–900 (2017). b 50 and 600 (2025) | IV [7]; [4] |
| Plane and thickness | Axial; coronal DWI not recommended; maximum slice thickness 5 mm | V [7] |
| ADC thresholds | Not given in the sources read | (to be sourced) |
Interpretation limits: restricted diffusion is supportive but nonspecific [5]; active Crohn's disease should not be diagnosed on restricted diffusion alone, normal jejunum shows more non-focal restricted diffusion than normal ileum, and suboptimal distension can produce false-positive restricted diffusion [6]; fibrosis can also restrict diffusion [4]. Sequence principles: DWI (9012), EPI-DWI (9014), EPI (9010).
10.4 T1-Weighted 3D Fat-Suppressed, Pre- and Post-Contrast
| Parameter | Value stated | Source |
|---|---|---|
| Dimension and thickness | 3D; maximum slice thickness 3 mm for axial and coronal series | V [7] |
| Order | Non-enhanced coronal first; then contrast-enhanced coronal and axial | V [7] |
| Contrast | Pump injection 2 ml/s; 0.1–0.2 mmol/kg | V [7] |
| Timing | Enteric 45 s or portal venous 70 s (2017); 60–70 s (2025) | V [7]; [4] |
| Status | Recommended (2017); optional (2025) | [7]; [4] |
The sequence principles are in GRE / FLASH (9008) and the parameter concepts in MRI Parameters Overview (9501), Field of View (9581) and Slice Thickness (9583).
11. Evidence Gaps and Ongoing Debate
Inflammatory versus fibrotic strictures: the ECCO-ESGAR guideline states that "no imaging modality can fully assess whether a stricture is inflammatory or fibrotic in nature" [2]. A 2023 meta-analysis of 22 studies (7,437 records screened) reports pooled sensitivity 85.2% (95% CI 76.1–91.2) and specificity 96.0% (87.8–98.7) for detecting fibrotic strictures, 81.5% (70.2–89.2) and 97.2% (90.0–99.3) for differentiating fibrotic from inflammatory stenosis, and 90.4% (78.1–96.1) and 89.4% (57.4–98.2) for stricture severity, and concludes that MRI has strong diagnostic accuracy and that larger multicentre trials are needed [8]. Only the abstract was read; the reference standards, heterogeneity and risk of bias of the included studies were not extracted, and the confidence interval for specificity of severity grading is wide. A 2019 systematic review by the STAR Consortium on the same question exists [10]; its content was not read. The two statements are not reconciled in the sources read.
Is intravenous gadolinium mandatory? The 2017 consensus lists pre- and post-contrast T1 among the recommended sequences [7], the 2025 recommendations list them as optional and say intravenous contrast is not essential [4], and the SAR/AGA panel accepts a non-contrast protocol with a weak recommendation [6]. No source read compares diagnostic outcomes of contrast-enhanced and non-contrast protocols; the abbreviated non-contrast meta-analysis found in the search was not read (to be sourced).
Role of DWI and cine motility: both are optional and routine use was not agreed [7]. DWI is supportive and nonspecific [5, 6]; no ADC threshold was found (to be sourced). The evidence for motility rests on a study cited in [4] and not read.
Spasmolytic agent and dose: the comparison read is a 10-volunteer crossover study in which glucagon 1 mg produced complete arrest in 10 of 10 and hyoscine 40 mg in 5 of 10 [13]; the consensus recommends hyoscine first [7]; the consensus doses differ from the US glucagon label and the UK hyoscine label for children [7, 16, 17]. No randomised comparison in patients with image-quality endpoints was found.
Oral contrast: the agent comparison is observational [14]; no consensus on a minimum volume was reached and the splitting of the dose has no consensus [7].
MRE versus ultrasound and capsule endoscopy: METRIC found higher MRE accuracy for disease extent [12]; the ECCO-ESGAR guideline states that MRE and intestinal ultrasound have similar value for monitoring transmural healing, that the first-line choice depends on local availability and expertise, and that small bowel capsule endoscopy yield was comparable to MRE except in the proximal small bowel, where capsule appeared superior [2]. An ECCO news item of April 2025 presenting the 2025 guideline states that the role of intestinal ultrasound is expanded to initial diagnosis and monitoring and does not mention MRE [1]; the statements of the 2025 guideline itself were not read.
Activity scores: the original MaRIA publication was not read; sMaRIA thresholds come from a news report of a single-centre derivation and validation [18]; in a retrospective study of 67 patients the AUCs of MaRIA, sMaRIA and Nancy were all between 0.75 and 0.77 [15]; no source read gives thresholds for MaRIA.
Small intestinal tumours: the meta-analysis of 8 articles (551 cases) reports no heterogeneity on its tests and a fixed-effect model; its authors list limitations (Chinese- and English-language papers only, variable study quality, unpublished literature not accessed), and its quality assessment found that items on intermediate test results and withdrawals were often not met [9].
Early postoperative recurrence and mucosal disease: MRE cannot assess aphthoid ulcers [2].
Not covered by any source read: coeliac disease, chronic gastrointestinal bleeding accuracy, safety of the oral load in high-grade obstruction, incidental findings, patient-instruction wording, and the 2025 guideline statements (to be sourced).
11.1 Paediatric Statements of the Joint ESGAR/ESPR Consensus
These statements come from the 2017 consensus [7]; the paediatric ECCO-ESGAR-ESPGHAN-IBUS guideline was not read, and the text read gives no statement for children under 6. The ECCO-ESGAR guideline adds that "MR enterography is also safe and well tolerated in paediatric populations" [2].
| Item | Statement |
|---|---|
| Fasting | No solid food for 2–4 h at age 6–9 years; 4–6 h over 9 years; no fluid restriction (V) |
| Oral contrast | 20 ml/kg, up to a maximum of 25 ml/kg (V) |
| Spasmolytic | Optional; if used, hyoscine butylbromide 0.5 mg/kg IV, or glucagon 0.5 mg (<24.9 kg) or 1 mg (>24.9 kg) by slow infusion with saline at 1 ml/s; a statement recommending the spasmolytic in children did not reach consensus (V) |
| Gadolinium | 0.1 mmol/kg (V) |
| Total scan time | 45 min or less (V) |
12. Evidence-Based References
References are ordered by level of evidence and then by recency. The reading level of each source is stated in its line; a source read only at abstract level supports only what its abstract states.
A. Guidelines / Consensus / Society Recommendations
B. Systematic Reviews / Meta-analyses
C. Important Prospective / Original Studies
D. Technical MRI Papers
No technical-development paper specific to MR enterography was read for this page (to be sourced). Technical statements rest on [7].
E. Landmark Historical References
No landmark historical reference was read for this page (to be sourced).
F. Product Information and Secondary Reports
Child Protocols
Clinical pages derived from this master protocol. These pages document what changes for specific indications.
No child protocols have been published yet.
Related Protocols
Recent PubMed search for this protocol