What Is MRI in Clinical Diagnostics? An Introduction for Newcomers
MRIninja Knowledge Base | Orientation — Introduction for Newcomers Parent page: MRI Physics — Fundamentals and Principles (9201) Version 1.1 — November 2026
Orientation — Introduction for Newcomers
What Is MRI in Clinical Diagnostics?
The purpose of magnetic resonance imaging as a clinical specialty, written for readers who are new to it: what an MR examination is, what an MR image does and does not measure, the kinds of clinical question it is used for, how it compares with CT, what happens during an examination, where its hazards come from, and who is responsible for what.
1. Scope, Boundary and Information Status
This page is the entry point of the library. It names each topic only at the level a newcomer needs and then points to the page that holds it, so that nothing here repeats what the specific pages state. The physics is on MRI Physics — Fundamentals and Principles and its child pages, the machine is on MRI Scanner Structure and Components — Overview, the sequences are on MRI Sequences — Overview and Classification, the acquisition parameters are on MRI Parameters — Overview and Classification, contrast media are on Contrast Media in MRI, and patient preparation is on the Patient Preparation page. The safety hazards each have a page, listed in Section 8.
This page is the home of the overall purpose of MRI as a diagnostic specialty, the plain-language description of what an MR examination and an MR image are, the survey of clinical uses, the comparison with CT at survey level, the outline of an examination, and the roles of the professionals involved.
Information status. Twenty-one sources were read. No guideline, consensus statement or systematic review answers the question "what is MRI", so the page rests on descriptive sources and says so. Six are regulatory or professional guidance: the ACR practice parameter for performing and interpreting MRI, amended 2023 [1]; the personnel definitions of the ACR Manual on MR Safety, 2020 version [2]; two ICNIRP statements on the protection of patients, 2004 and 2009 [3, 4]; the European Commission referral guidelines for imaging, published in 2000 [5]; and the FDA pages on MRI [6]. Two are medical-society or professional-reference texts: RadiologyInfo.org, run by the ACR and the RSNA [7], and the MSD Manual Professional Edition [8]. Eight are educational or review texts [9–16] and five are patient-information pages of health services and the EU-OSHA wiki [17–21]. Almost all were read through a tool that returns a model-written answer about the page, not the raw text; the reading level of each is given in Section 13. Several sources are patient-information or reference texts, not studies, and the FDA pages are marked as current to 2017.
Three attempts to read sources failed and were not worked around: the fact sheet of the US National Institute of Biomedical Imaging and Bioengineering (two addresses, refused to automatic readers), the StatPearls chapter on MRI physics and the PMC copy of an ICNIRP statement on diagnostic non-ionising devices (both stopped by a browser check). The numbers in this page come from the sources listed; where a statement is the editor's own reasoning it is marked (Reasoning).
2. What MRI Is, in Plain Terms
MRI stands for magnetic resonance imaging. The ACR practice parameter defines it as a multiplanar imaging method in which radiofrequency fields interact with certain nuclei in the body, usually hydrogen nuclei, after the body has been placed in a strong magnetic field, and which distinguishes normal from abnormal tissue by differences in magnetic relaxation properties [1]. A public-science explainer from the US National Institute of Standards and Technology describes the same sequence for a lay reader [10]: the body contains many protons, mostly in water but also in proteins and fat; each acts as a tiny magnet; the scanner's magnetic field lines up many of them; a radiofrequency pulse of a matching frequency (the "resonance") tips them out of alignment; as they return ("relax") they emit weak electromagnetic signals that carry information about where they are and about the tissue around them; magnetic fields that vary in space (gradients) let the machine encode where each signal comes from; and computers combine the signals of many repetitions into images [10]. The MSD Manual adds that the energy release is measured as T1 relaxation (return to the original alignment) and T2 relaxation (loss of the precessing signal), that a coil in the scanner records the signals, and that computer algorithms convert them to anatomic images [8].
The examination uses no x-rays or other ionising radiation [6, 7, 8]. That fact is correct and is the reason MRI is often described as "safe", but it says nothing about the other hazards of the method, which are listed in Section 8.
2.1 The ingredients, one by one
| Ingredient | What it does in the examination | Sources |
|---|---|---|
| Strong static magnetic field | Aligns a fraction of the hydrogen nuclei; the field is always present around the magnet, so the patient and everything entering the room are exposed to it | [1, 8, 10] |
| Radiofrequency pulses and a receiver coil | The pulses disturb the alignment; the coil records the weak signal emitted afterwards. The RF energy can heat the body, more so in long examinations and when implants or cables are in the bore | [3, 6, 8, 10] |
| Gradient fields (fields that change in space and time) | Encode the position of each signal; their switching makes the loud knocking of the examination and can stimulate nerves or muscles | [3, 6, 10, 17] |
| Computer reconstruction | Turns the recorded signals into images | [8, 10] |
How each ingredient works physically is on the physics pages (nuclear magnetic resonance, relaxation, RF pulses, localisation and k-space); how the machine produces them is on the scanner overview.
3. What an MR Image Shows, and What It Does Not Measure
3.1 Brightness is relative and depends on the sequence
The relative brightness of a tissue in an MR image depends on the radiofrequency pulse and gradient waveforms used, on the tissue's own T1 and T2 characteristics, and on its proton density; the computer program that controls these elements is a pulse sequence, and the sequence determines whether the image is T1-weighted, T2-weighted or proton-density-weighted [8]. One examination is therefore not one picture but a set of series made with different sequences, often in different planes. A teaching series from a university department states that there are over 100 different MRI sequences and that the same tissue looks different on different ones [15]. The ACR parameter asks that the images have suitable contrast, spatial resolution, signal-to-noise ratio and anatomic coverage [1].
| Tissue | T1-weighted image | T2-weighted image | Sources |
|---|---|---|---|
| Fluid (for example cerebrospinal fluid) | Dark | Bright | [8, 11, 15] |
| Fat | Bright | Described as dark [8, 15], and as intermediate to bright [14]; see Section 3.3 | [8, 11, 12, 14, 15] |
The same sources give the clinical use of the two weightings in one line each: T1-weighted images show normal soft-tissue anatomy and fat best (for example to confirm that a mass contains fat), and T2-weighted images show fluid and abnormalities such as tumour, inflammation and trauma best; the MSD Manual states that they are complementary and both are needed to characterise an abnormality [8]. The OpenLearn course adds that T2-weighting is used especially to show disease because water tends to accumulate in diseased tissue and appears bright against normal tissue, and that T2-weighted images have a poorer signal-to-noise ratio [11]. The page on sequences and the pages on contrast-forming parameters hold the detail.
3.2 An MR image is mostly a picture, not a measurement
The NIST explainer says that MRIs mostly provide qualitative information, that is, pictures, and that quantitative MRI, which aims to give measurements, is used in some clinical trials and settings such as liver disease [10]. A course lecture states that images of the actual T1 or T2 values of tissue are typically not made; the "weighted" images enhance the effect of one property while minimising others [16]. A review of the signal and contrast of MR images adds that the terms T1-weighted and T2-weighted are qualitative, name a single dominant property and can mislead: the same sequence may be called T1-weighted for brain but is effectively T2-weighted for a tendon [9]. (Reasoning) For a newcomer this means that "bright" and "dark" in a report are statements about contrast between neighbouring tissues on a given sequence, not about a fixed property of the tissue; the same lesion can be bright on one series and dark on another.
3.3 What gives little signal
The review of Young and colleagues gives the fraction of protons that are mobile enough to be detected as about 15–20 % in bone, about 70–90 % in soft tissue and close to 100 % in relatively pure fluids, and a T2 of about 0.3–0.5 ms for cortical bone against 2,000–3,000 ms for cerebrospinal fluid [9]. The FDA states that MRI gives better soft-tissue contrast than CT and distinguishes fat, water, muscle and other soft tissues more clearly, and that CT is usually better for bones [6]. (Reasoning) The very short T2 of cortical bone is consistent with its giving almost no signal on routine sequences; the sources read do not state that link explicitly.
The appearance of fat on T2-weighted images is a point on which the sources differ. Two educational sources describe fat as dark on T2 [8, 15]; a 1992 study reports anomalously high signal of fat on fast spin-echo images, which it attributes to the repeated refocusing pulses [12], and a web resource on the same effect states that fast spin-echo has largely replaced conventional spin-echo, which is why fat-suppressed T2-weighted images are routine [13]; an open reference article lists fat on T2-weighted images as intermediate to bright [14]. (Reasoning) The two descriptions probably refer to conventional and to fast spin-echo sequences; the sources read do not say which one the two educational texts mean. See the page on chemical shift and fat–water physics for fat suppression.
4. What MRI Is Used For
The FDA lists the diagnostic uses of MRI as abnormalities of the brain and spinal cord; abnormalities in other parts of the body such as breast, prostate and liver; injuries or abnormalities of joints; the structure and function of the heart; areas of activation within the brain (functional MRI); blood flow in vessels (angiography); and the chemical composition of tissues (spectroscopy); it adds that MRI may also be used to guide certain interventional procedures [6]. The applications that lie outside the routine examination (nuclei other than hydrogen, spectroscopy, radiotherapy, focused ultrasound, biopsy under MRI, fetal imaging, functional MRI, elastography) are surveyed, with their stated status, on page 9215. RadiologyInfo and the MSD Manual give the following examples, which are a survey and not a list of indications [7, 8].
| Area | Examples named in the sources | Sources |
|---|---|---|
| Brain and head | Stroke and its damage, changes of ageing, brain damage or bleeding after trauma, brain tumours, developmental anomalies, hydrocephalus, causes of epilepsy, infection, multiple sclerosis, eye and inner-ear disorders, pituitary disorders; brain vessels by MR angiography, often without contrast material; mapping of motor and language cortex before surgery by functional MRI; diffusion imaging for early ischaemia | [7, 8] |
| Spine and spinal cord | Spinal cord abnormalities; the spine for back pain | [5, 6, 7, 8] |
| Joints, muscle and bone | The major joints (usually together with conventional radiographs), cartilage, meniscus, ligament and tendon damage, soft-tissue tumours, bone marrow abnormalities and metastases, some fractures that radiographs show poorly | [7, 8] |
| Abdomen and pelvis | Liver, bile ducts and pancreas (including MR cholangiopancreatography, which shows the ducts without contrast injection), kidneys, spleen, bowel inflammation such as Crohn disease, adrenal glands, bladder and reproductive organs, tumours, lymph nodes; the female pelvis as a complement to ultrasound; a fetus during pregnancy | [7, 8] |
| Heart and vessels | Structure and function of the heart; MR angiography of the aorta and the arteries of the neck, abdomen, kidneys and legs; MR venography | [6, 7, 8] |
| Metabolism, function and guidance | Spectroscopy, functional imaging, perfusion imaging for ischaemia and tumour vascularity, guidance of interventional procedures | [6, 8] |
These applications are described at protocol level on the clinical pages of the library, for example brain, lumbar spine, knee, liver, prostate, heart and thoracic vessels. Uses outside routine diagnostic imaging (for example imaging of nuclei other than hydrogen, spectroscopy, planning of radiotherapy and guidance of focused-ultrasound treatment) are only named here.
4.1 When MRI is chosen
The ACR parameter says that the choice of MRI depends on the available hardware and software, cost, efficacy and the availability of alternatives, and that the appropriateness of an examination is a shared responsibility of the ordering provider and the radiologist [1]. The European Commission's referral guidelines, published in 2000 and therefore old, state that MRI should be preferred over CT when both would give similar information and both are available, and that ultrasound is the appropriate first investigation wherever possible because it avoids ionising radiation and is inexpensive; they also state that a useful investigation is one whose result will change management or add confidence to the diagnosis [5]. In that document three examples are graded "indicated": demyelinating and other white-matter disease (grade A, MRI much more sensitive than CT), posterior-fossa signs (grade A, MRI much better than CT) and myelopathy from tumour, inflammation, infection or infarction (grade B, MRI the clear first choice for spinal cord lesions) [5]. The current European and American appropriateness tools were not read (Section 14).
5. MRI Compared with CT, at Survey Level
| Feature | MRI | CT | Sources |
|---|---|---|---|
| Ionising radiation | None | Uses x-rays (an ionising radiation) | [6, 7, 8] |
| Soft-tissue contrast | Better; distinguishes fat, water, muscle and other soft tissues more clearly | Less | [6, 8] |
| Bone | Less well shown | Usually better | [6] |
| Examination time | Longer | Shorter | [7, 8] |
| Cost and availability | Relatively expensive; not available everywhere | Less expensive, more available | [7, 8] |
| Contrast agent reactions | Gadolinium agents: serious reactions rare and much less common than with iodinated agents; nephrogenic systemic fibrosis rare, mostly in advanced kidney disease | Iodinated agents: more reactions | [7, 8] |
| Metal, implants and the magnet | Implants may move, heat or malfunction; the examination is contraindicated or conditional for some | Not addressed in the sources read | [6, 8] |
| Cooperation | Stillness and, for body examinations, breath-holds are needed; noise and the narrow bore are poorly tolerated by some | Shorter examination (see the row on time); otherwise not addressed in the sources read | [6, 7, 8] |
The CT column is filled only with what the sources state about the comparison; the sources read do not give a complete description of CT. Several rows summarise statements made in the context of a particular organ or technique (for example the MSD statement that a lack of ionising radiation is an advantage for enterography [8]) and do not support a general rule for every examination. MRI is also not simply a replacement for CT: the MSD Manual states that it can be substituted for contrast-enhanced CT in patients at high risk of reaction to iodinated contrast [8].
6. A Typical Examination, in Outline
This is the sequence of events as the patient-information sources describe it; the preparation itself is on the Patient Preparation page.
- Request and screening. The request must establish medical necessity and come from a physician or an appropriately licensed provider; all patients must be screened before scanning for implants and devices [1]. The patient is asked about health problems, surgery, allergies, possible pregnancy and any device or metal in the body, removes jewellery and metallic clothing and often changes into a gown [7].
- Positioning. The patient lies on a table that moves into the scanner, head first or feet first depending on the part examined [18]. A radiographer controls the scanner from another room and can hear and speak to the patient [17]; the patient is given a call button [19].
- Acquisition. A number of sequences are run one after another. Each makes a loud noise, described as knocking, which the FDA attributes to the time-varying magnetic fields [6]; earplugs or headphones are provided [19]. The patient must stay still, and body examinations may need breath-holds; movement or an inability to hold the breath blurs images [7, 18].
- Contrast agent, if used. A gadolinium agent may be injected into a vein before or during the examination [7].
- After the examination. A radiologist interprets the images and sends a report to the physician who requested the examination; many services also release it to a patient portal [7]. A further examination may be needed to look more closely, to check change over time or to see whether treatment is working [7].
Duration. Patient-information pages give different figures: 15 minutes to 1 hour, "but can take longer" (NHS England) [17]; 15 to 90 minutes (NHS 111 Wales) [18]; 10 to 45 minutes of image acquisition (one hospital trust) [20]; and the RadiologyInfo pages read do not state a duration [7]. A single scan, one series within the examination, may take from a few seconds to 3 or 4 minutes according to NHS 111 Wales [18]. (Reasoning) The spread reflects the part examined and the number of series; it is not an error of any one source. The factors that set the scan time of a single series are on the parameter pages (see MRI Parameters).
7. Strengths and Limits
| Strengths | Limits | Sources |
|---|---|---|
| No ionising radiation | Magnetic field, radiofrequency heating, noise and gradient effects are specific hazards (Section 8) | [6, 7] |
| Images of any part of the body in any imaging direction | Cost, examination time and availability | [6, 7, 8] |
| Detailed soft-tissue contrast; many different contrasts from one examination | Image quality depends on stillness; anxiety, confusion or severe pain can prevent it; infants and young children may need sedation or anaesthesia | [6, 7, 8, 18] |
| Vessels, ducts and some functions can be shown without a contrast injection | Implants and other metal can obscure the image as well as being a hazard; large patients may not fit some scanners, which have weight limits | [6, 7] |
| Functional, metabolic and perfusion information in selected cases | Claustrophobia in the bore; open-side scanners help some patients but not all systems perform all examinations | [6, 7, 8] |
8. Safety in Outline
MR examinations are not free of hazards: each of the three fields has its own, and the FDA lists the main sources of adverse events as projectile events and device motion from the static field, tinnitus or hearing loss from noise, peripheral nerve stimulation from the changing fields, heating or burns from radiofrequency energy (more likely when implants, other devices or coil cables are in the bore), crush and pinch injuries and falls from the table [6]. ICNIRP's statement on patient protection likewise considers the three field types separately [3]. The following table maps each hazard to the page that is its home.
| Source of hazard | What the sources name | Home page | Sources |
|---|---|---|---|
| Static field | Attraction of magnetic objects (projectiles); forces on implants; malfunction of active devices | projectile and torque hazards, field contours, active implants, passive implants | [3, 6, 8] |
| Gradient fields | Noise; peripheral nerve stimulation | gradient fields, acoustic noise | [3, 6] |
| Radiofrequency | Heating; burns, especially with implants and cables | SAR and bioeffects | [3, 6, 8] |
| Contrast agents | Allergic-type reactions, nephrogenic systemic fibrosis, small amounts of gadolinium that may remain in the body | gadolinium agent safety | [7, 8] |
| Bore and sedation | Claustrophobia, sedation risk | claustrophobia, sedation and emergencies | [6, 7, 8] |
| Pregnancy | Individual decision; gadolinium avoided unless needed | MRI in pregnancy | [1, 3, 7] |
| Cryogens | Quench and oxygen depletion | cryogens, quench and oxygen depletion | [8] (quenching is named only as a way to free an object) |
| Site and access | Who may work in the controlled area (personnel levels); the zones themselves are not defined in the text read | MR site zones and access control | [2] |
How often harm occurs. The FDA states that adverse events are very rare although millions of scans are done each year in the United States, that it receives about 300 adverse-event reports a year for MRI scanners and coils, that most reports involve heating or burns, and that second-degree burns are the most common patient problem [6]. These are reports to a regulator, not an incidence; the page is marked current to 2017 and covers the United States only. The FDA also states that with careful attention to safety procedures these events are almost entirely preventable [6].
What the field exposure is known to do. ICNIRP's 2004 statement found no serious adverse health effects of whole-body exposure of healthy adults to static fields up to 8 T, with dizziness reported by some volunteers at 8 T, and recommended three tiers of exposure (normal, controlled and experimental operating mode) [3]. Its 2009 amendment kept the three tiers, repeated that current information does not indicate serious health effects from acute exposure up to 8 T, noted vertigo and nausea with movement in the field, advised that patients be moved slowly into the bore, and stated that no long-term epidemiological data exist [4]. The limits in numbers belong to SAR and bioeffects.
The device rule. An implant should not go into the MR environment unless it has been confirmed as MR Safe or MR Conditional and, for MR Conditional, all conditions are met; a device whose status is unknown is assumed to be unsafe [6].
9. Who Does What
| Role | What the sources say | Sources |
|---|---|---|
| Radiologist (supervising physician) | Responsible for all aspects of the study: reviewing the indication, specifying pulse sequences, interpreting the images, issuing the final report and the quality of images and interpretation; in the FDA text, weighs the benefit and the risk of each examination, including all devices the patient carries | [1, 6] |
| Technologist (radiographer) | Ensures patient comfort and safety, prepares and positions the patient, acquires data suitable for interpretation, performs the frequent quality-control checks; screens patients and knows the site's safety procedures and the MR safety officer | [1, 6] |
| Medical physicist or MR scientist | Responsible for acceptance testing and monitoring of the equipment; must approve all measurements of the surveys | [1] |
| MR Medical Director, MR Safety Officer, MR Safety Expert | Three safety roles of the ACR Manual: the Medical Director has overall and ultimate responsibility for the safety of the facility; the Safety Officer is usually an MR technologist who enforces the policies, writes working and emergency procedures and keeps training records; the Safety Expert is an advisory role, often an MR physicist, who may be external | [2] |
| Safety education levels | Level 1 personnel have the education needed to keep themselves safe in the controlled area (Zone III); Level 2 personnel have broader training (examples: technologists, radiologists, radiology nursing staff) | [2] |
The EU-OSHA wiki, a European occupational-safety text, assumes that ultimate operational responsibility lies with a single individual, the MR Medical Director or MR Research Director, that the Safety Officer role is often carried out by the senior radiographer, and that the Safety Expert may be external [21]. The qualification routes and titles in these sources are those of the United States and, for the wiki, a European text; titles, credentials and the division of work differ between countries (Section 14).
10. Common Misunderstandings
| Statement | What the sources say | Sources |
|---|---|---|
| "MRI has no risks because it uses no radiation." | It uses no ionising radiation, but the static field, noise, gradients, radiofrequency heating and contrast agents each carry hazards that are preventable by screening and procedure | [6, 7] |
| "The magnet is switched off when nobody is being scanned." | The magnetic field may always be on; ferromagnetic objects near the entrance can be pulled into the bore at high speed | [8] |
| "An MR image measures the density or the type of a tissue." | Brightness is relative and depends on the sequence; images are mostly qualitative, and quantitative MRI is a developing area | [8, 9, 10, 16] |
| "MRI replaces CT." | MRI is preferred where soft-tissue contrast or avoidance of ionising radiation matters, CT is usually better for bone and is faster; choice depends on the question, availability and cost | [1, 5, 6, 8] |
| "Everything that is brighter on the image is abnormal." | Brightness depends on the weighting: fluid is bright on T2 and fat on T1 in normal anatomy | [8, 11] |
| "Metal in the body always excludes MRI." | Most orthopaedic implants pose no risk, and MR Conditional devices may be scanned if the conditions are met; unknown devices are treated as unsafe | [1, 6, 7] |
11. Where to Go Next
The library is organised in areas, and the Academy gives a guided order. A reader who wants the physics begins with MRI Physics — Fundamentals and Principles; a reader who works at the scanner begins with the scanner overview and the Patient Preparation page; a reader who wants to understand the images begins with the sequence overview and the parameter overview. The Academy places this page at the start of its first level, followed by the pages on the scanner and the MR suite.
12. Discrepancies Between Sources
| Topic | One source | Another source | Handling on this page |
|---|---|---|---|
| Fat on T2-weighted images | Dark [8, 15] | Anomalously bright on fast spin-echo [12]; intermediate to bright [14] | Both given; probably conventional against fast spin-echo (Reasoning) |
| Duration of an examination | 15 minutes to 1 hour [17] | 15 to 90 minutes [18]; 10 to 45 minutes of acquisition [20] | All given; depends on the part and the number of series |
| Kidney-function screening before gadolinium | MSD Manual: the ACR and National Kidney Foundation consensus states that screening is not mandatory for any patient receiving Group II agents [8] | ACR parameter: screening is required to reduce the risk of nephrogenic systemic fibrosis unless a cyclic agent is used [1] | Not resolved here; the home is gadolinium agent safety |
| Safety officer in ACR documents | The ACR Manual defines the MR Safety Officer [2] | The ACR practice parameter does not define a separate MR safety officer and assigns safety responsibilities to the supervising physician [1] | Two different documents with different scope; both stated |
| Currency of FDA pages | Content current as of December 2017 [6] | Page metadata shows a 2022 date [6] | Figures such as the 300 reports a year are given with the date |
| Age of the European referral guidelines | Published in 2000 [5] | Newer appropriateness tools exist and were not read | Used only for the general principles and the grading of three examples, marked as old |
13. Open Questions
The terms T1-weighted and T2-weighted are widely used and also criticised as qualitative and ambiguous [9]; the page uses them as the sources do and flags where they mislead. How much information about the weaker points of the evidence a patient-information page should give is a matter of editorial choice: RadiologyInfo states that the exposure carries "almost no risk" for the average patient when safety guidelines are followed [7], whereas the FDA text lists a range of preventable injuries [6]. The two statements are compatible but have a different emphasis.
14. Evidence Gaps
- No guideline, consensus statement or systematic review was found that defines MRI for a general reader; the page therefore rests on professional and educational texts and the ACR practice parameter. (to be sourced) if a better definition source is wanted.
- The current appropriateness tools that say which modality suits which clinical question (the ACR Appropriateness Criteria, the ESR iGuide) were not read; only the European Commission document of 2000 was read, and only its first 100,000 characters of 211,632 through a tool.
- The NIBIB fact sheet (refused to automatic readers at two addresses), the StatPearls chapter on MRI physics and the PMC copy of an ICNIRP statement (browser check) were attempted and not read; they were not circumvented.
- Typical examination times were taken from patient-information pages (search extracts or tool summaries); no study of actual examination times was read.
- The roles of the technologist, radiologist and physicist are described from United States documents and one European wiki; the legal titles and scope of practice in Italy, France and other countries were not sourced. (to be sourced)
- The share of examinations that are first-line MRI, the number of examinations per country and the cost were not sourced and are not stated.
- The figures of Young et al. on mobile proton density and on the T2 of bone were read from the first 100,000 of 227,926 characters of the review only [9].
15. Evidence-Based References
No guideline or study with an EBM level defines this introductory page. Sources are ordered by type and quality; the reading level of each is stated. Patient-information pages are used for what happens in an examination, not as evidence of effect.