Sequences and Technical Parameters
Pulse sequences, acquisition parameters and special techniques (angiography, diffusion, perfusion, vessel wall), organised by technique rather than by organ.
Master main page of a topic; its child pages are indented below it. ⌕ Focus in-depth article attached to a page. HV = Human Verified progress (share of the page reviewed by human experts).
Sequences: Overview 1
Classification of MRI sequences.
Master reference page for MRI sequence taxonomy, readout architecture, contrast mechanisms, vendor naming conventions and protocol-design logic
Spin Echo and Inversion Recovery 6
SE, TSE, IR, STIR and FLAIR.
Sequence child page covering Spin Echo, TSE/FSE physics, parameters, tissue contrast, artefacts and clinical applications
Sequence-specific technical reference linked to the MRI sequences overview master page
Sequence-specific technical reference for STIR fat-nulled inversion recovery MRI
Deep dive on the deliberate use of gadolinium-based (or ferumoxytol) T1/T2-shortening contrast agents to suppress vascular signal on STIR, exploiting the fact that STIR nulls any tissue whose T1…
Sequence-specific technical reference for FLAIR CSF-nulled inversion recovery MRI
Sequence-specific technical reference linked to the MRI sequences overview master page
Gradient Echo and Steady State 5
GRE, MPRAGE, bSSFP, SWI and QSM.
Sequence-specific technical reference for Gradient Echo / FLASH MRI
Placeholder sequence child page linked to the MRI sequences overview master reference page
Sequence-specific technical reference for SWI susceptibility-weighted gradient echo MRI
Full technical deep dive on Quantitative Susceptibility Mapping (QSM): the phase-to-susceptibility inversion problem, the three-stage processing pipeline (phase unwrapping, background field removal…
Technical sequence page on balanced steady-state free precession (bSSFP): gradient balancing, alternating RF train and TE = TR/2, T2/T1 contrast and optimal flip angle, transient phase and start-up…
EPI and Diffusion 4
Echo-planar imaging and diffusion-weighted techniques.
Placeholder sequence child page linked to the MRI sequences overview master reference page
Placeholder sequence child page linked to the MRI sequences overview master reference page
Placeholder sequence child page linked to the MRI sequences overview master reference page
Placeholder sequence child page linked to the MRI sequences overview master reference page
Angiography and Flow 8
TOF, phase contrast, non-contrast angiography and flow physics.
Technical page on triggered (ECG- or pulse-gated) non-contrast-enhanced MR angiography: how the arterial pulse replaces contrast agent as the signal mechanism; cardiac-gated 3D fast spin-echo…
Deep dive on inflow inversion-recovery balanced SSFP non-contrast angiography: Philips b-TFE / B-TRANCE naming and its distinction from TSE-based TRANCE; region versus Time-SLIP inversion geometry…
Deep dive on ASL-based non-contrast angiography: how angiographic ASL differs from perfusion ASL; pulsed (4D-TRANCE, mASTAR), pseudo-continuous (4D-PACK, 4D-S-PACK, 4D-APACK), time-encoded and…
Technical page on phase-contrast MRI in practice: how the velocity-encoded data are formed; VENC selection rules and their opposite optimisation for morphology (PC-MRA / MRV) and quantification; 2D…
Quantitative physics of the inflow effect (flow-related enhancement) and the outflow effect (time-of-flight signal loss, washout): spoiled gradient-echo magnetisation recursion, fresh-to-stationary…
Technical page on time-of-flight MR angiography in practice: choice between 2D, 3D and multi-slab acquisition, angiography-specific parameters (venous saturation, ramped excitation, magnetization…
Quantitative deep dive on ramped (TONE) excitation in 3D TOF-MRA: constant-signal flip-angle profile, linear ramps against uniform angles, velocity dependence, effect on the stationary background…
Deep dive on maximum intensity projection in angiography: what the pixel value is, noise-elevated background in long rays, threshold-dependent apparent vessel width and stenosis, depth collapse and…
Perfusion 2
Arterial spin labelling.
Master protocol for arterial spin labeling (ASL) — non-contrast, quantitative cerebral blood flow (CBF) perfusion MRI using PCASL labeling, background suppression, 3D segmented readout, and M0…
Technical deep dive on ASL labeling scheme parameters — STAR, FAIR, pCASL, STAR Angio/Time-SLIP — with full cross-vendor terminology mapping (Philips, Siemens, GE) and worked examples verified…
Vessel Wall Imaging 2
Universal technique master and vascular wall anatomy.
Territory-agnostic master reference for MRI vessel wall imaging (VWI): the shared black-blood physics (DIR, MSDE, DANTE), the multi-contrast plaque/wall characterisation principle originating in…
Signal-only MR semiotics of the three-layer vessel wall complex — lumen, wall, and perivascular tissue — restricted strictly to directly visible signal findings validated against histology: flow…
Parameters: Overview 1
Classification of acquisition parameters.
Master reference page for MRI acquisition parameters, protocol optimisation trade-offs, timing, spatial resolution, acceleration, synchronisation and reconstruction logic
Parameters: Geometry and Sampling 9
Field of view, matrix, slices, 2D and 3D acquisition.
Focused technical deep dive on Field of View as an MRI acquisition parameter, including k-space encoding, voxel size, aliasing, SNR, CNR, acquisition time and sequence-specific optimisation.
Focused technical deep dive on acquisition matrix as an MRI acquisition parameter, including k-space sampling, spatial resolution, SNR/CNR, acquisition time, TSE/EPI behaviour and sequence-specific…
Focused technical deep dive on slice thickness as an MRI acquisition parameter, including slice selection physics, partial volume, SNR/CNR, cross-talk, 2D versus 3D acquisition and sequence-specific…
Focused technical deep dive on the 2D versus 3D acquisition choice in MRI protocol design, including z-encoding, SNR efficiency, MPR capability, motion sensitivity, artefacts and sequence-family…
Focused technical deep dive on reconstruction matrix, pixel interpolation, zero-filling and slice interpolation in MRI protocol design.
Focused technical deep dive on number of slices as an MRI acquisition parameter, including the 2D TR-slice-loop-time ceiling, concatenations/packages, 3D partition scan-time cost, SAR coupling…
Focused technical deep dive on inter-slice gap as an MRI acquisition parameter, including the RF slice-profile cross-talk mechanism, the missed-tissue-fraction coverage cost, interleaving as the…
Focused technical deep dive on slice scan order as an MRI acquisition parameter, covering temporal excitation order (sequential vs interleaved), spatial acquisition direction and its flow-related…
Focused technical deep dive on slice (partition) oversampling in the 3D slice-encoding direction — the through-slab analogue of in-plane phase oversampling — covering the boundary wrap-around and…
Parameters: Phase Encoding and Aliasing 3
Fold-over, phase oversampling and anti-aliasing.
Focused technical deep dive on phase oversampling, fold-over suppression, No Phase Wrap and aliasing prevention in MRI protocol design.
Focused technical deep dive on fold-over direction (phase-encoding direction) as an MRI acquisition parameter, covering the frequency vs phase-encoding physical asymmetry, wrap-around and…
Synthesis reference page bringing together every antialiasing tool on this platform — geometric/planning strategies (patient repositioning, in-plane FOV rotation, standalone phase-encoding direction…
Parameters: Scan Time, SNR and Bandwidth 6
Parallel imaging, signal averages and receiver bandwidth.
Echo spacing, turbo factor and echo trains per slice in turbo spin echo: what echo spacing is made of, trains and scan time, T2 blurring with a published point-spread model, effective TE, and console…
Partial Fourier in the phase direction and asymmetric (partial) echo in the readout direction: conjugate symmetry and its limits, reconstruction methods, lines, scan time and SNR, minimum echo time…
Calibration data and reference scans, controlled aliasing (CAIPIRINHA) in 3D, simultaneous multi-slice factor and FOV shift, published g-factor figures, and Siemens console labels
Focused technical deep dive on parallel imaging, SENSE, GRAPPA, g-factor, SMS and acceleration strategy in MRI protocol design.
Focused technical deep dive on NEX/NSA, signal averaging, SNR, acquisition time and motion averaging in MRI protocol design.
Focused technical deep dive on receiver (acquisition) bandwidth, covering in depth its three fundamentally different representations (Hz/pixel, total kHz, water-fat shift in pixels) with worked…
Parameters: Fat, Water and Fluid Signal 5
Presaturation, chemical shift and control of fluid signal.
Dixon water–fat separation: two-point model, in-phase and opposed-phase echo times at 1.5 and 3 T, the step to three or more echoes, output images, scan-time and contrast consequences, and Siemens…
Focused technical deep dive on REST slabs, presaturation bands, flow suppression, fold-over control and spatial saturation strategy in MRI protocol design.
Parameter-cluster anchor page reframing chemical shift around its two independently controllable acquisition parameters — receiver bandwidth (magnitude) and fat-shift direction (spatial axis) — as…
Parameter-level toolkit for deliberately controlling fluid signal on MRI: TR (background saturation vs. fresh-fluid contrast), TE (time-of-flight washout and intravoxel dephasing), flip angle (the…
- Fluid Signal Across Acquisition Strategies — 2D, Single-Slab 3D, and Multi-Slab (MOTSA) Compared⌕ FocusHV 0%
Comparative deep dive on how acquisition strategy itself — 2D multi-slice, 3D single-thick-slab, or 3D multiple overlapping thin-slab (MOTSA) — changes moving-fluid MR signal, independent of any…
Manufacturer-Specific Techniques 2
Techniques described for one manufacturer.
Parameter-by-parameter deep dive on the Philips MSDE black-blood preparation: BB pulse and MSDE mode, number and type of refocusing pulses, TEprep, and Venc on the RL, AP and FH axes; relation of…
Deep dive on radial blade acquisition and the Philips motion-tolerant sequences: blade geometry and coverage, estimation and correction of rigid motion and its limits, MultiVane versus MultiVane XD…